Plan Review Notes For Permit 20021291 |
Permit Number |
20021291 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2020-03-02 16:12:23 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | NOTE: SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK | | SHALL COMPLY WITH THE MATERIALS AND METHODS | | REQUIREMENTS IN THE FLORIDA BUILDING CODE. | | | | 1- FLAT ROOF FLORIDA PRODUCT APPROVAL FL16709-R6 | | SUBMITTED: | | INSULATED SYSTEM W-2 IS NOT APPLICABLE FOR THE PROPOSED | | APPLICATION. ACCORDING TO SEC. R301.2.1.4 | | FBC-RESIDENTIAL THIS BUILDING IS LOCATED IN EXPOSURE | | "C" NOT EXPOSURE "B" AS CIRCLED ON PRODUCT APPROVAL | | SUBMITTED. REVISE AS REQUIRED. | | ALSO, TABLE 2 OF W-2 SYSTEM ON PAGE 7 OF 14 INDICATES | | N/A FOR ROOF ZONE #3. THEREFORE, THIS SYSTEM CAN NOT BE | | USED. REVISE AS REQUIRED. NEED AN INSULATED ROOF | | ASSEMBLY THAT ALLOWS NAIL ENHANCEMENT AT PERIMETER AND | | CORNER AREAS FOR A BUILDING WITH THE SPECIFIED ROOF | | HEIGHT OF THIS BUILDING. SPECIFIED. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|