Plan Review Notes
Plan Review Notes For Permit 20021055
Permit Number 20021055
Review Stop B
Sequence Number 1
Notes
Date Text
2020-02-27 15:31:42RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW CHECKLIST.
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- FLAT ROOF NOA 20-0110.11 SUBMITTED: CLEARLY MARK
 WHICH APPROVED ASSEMBLY IS GOING TO BE INSTALLED TO
 VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC.
 R301.2.1 FBC-RESIDENTIAL. NOTE: IF THE SELECTED
 ASSEMBLY DOESN'T MEET THE DESIGN PRESSURES FOR ALL ROOF
 ZONES, THEN SIGNED AND SEALED RAS 117 CALCULATIONS ARE
 REQUIRED. SEE GENERAL LIMITATION #7 ON LAST PAGE OF
 NOA.
 NOTE: ASSEMBLIES THAT ARE LIMITED BY GENERAL LIMITATION
 #9 MAY NOT BE USED IF THE MAXIMUM DESIGN PRESSURES
 DON'T MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES.
 GENERAL LIMITATION #9 DOESN'T ALLOW NAIL ENHANCEMENT.
 SEE GENERAL LIMITATION #9 ON LAST PAGE OF NOA.
  
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,