Date |
Text |
2020-03-17 13:25:02 | POOL BARRIER |
| REVIEWED BY ROGER MCPHERSON |
| 561-805-6716 |
| [email protected] |
| |
| CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 |
| 1) POOL BARRIERS NEED TO COMPLY WITH FBC R4501.17.1 |
| 2) PLEASE SHOW CLEARLY WHERE THE FENCE IS ABUTTING THE |
| HOUSE FOR THE BARRIER LOCATION. IF THE FENCE IS |
| SURROUNDING THE ENTIRE PROPERTY ACTING AS THE POOL |
| BARRIER - THEN THE DRIVEWAY ROLL GATE WILL NEED TO |
| COMPLY WITH FBC R4501.17.1.8 |
| 3) PLEASE SHOW ROLL GATE TO COMPLY WITH FBC R4501.17.1 |
| - THE MAXIMUM VERTICAL CLEARANCE BETWEEN GRADE AND THE |
| BOTTOM OF THE BARRIER SHALL BE 2 INCHES (51 MM) |
| MEASURED ON THE SIDE OF THE BARRIER WHICH FACES AWAY |
| FROM THE SWIMMING POOL. (YOU SHOW 3 INCHES) |
| R4501.17.1.2 |
| THE BARRIER MAY NOT HAVE ANY GAPS, OPENINGS, |
| INDENTATIONS, PROTRUSIONS, OR STRUCTURAL COMPONENTS |
| THAT COULD ALLOW A YOUNG CHILD TO CRAWL UNDER, SQUEEZE |
| THROUGH, OR CLIMB OVER THE BARRIER AS HEREIN DESCRIBED |
| BELOW. OPENINGS IN ANY BARRIER SHALL NOT ALLOW PASSAGE |
| OF A 4-INCH-DIAMETER (102 MM) SPHERE. |
| R4501.17.1.4 |
| WHERE THE BARRIER IS COMPOSED OF HORIZONTAL AND |
| VERTICAL MEMBERS AND THE DISTANCE BETWEEN THE TOPS OF |
| THE HORIZONTAL MEMBERS IS LESS THAN 45 INCHES (1143 |
| MM), THE HORIZONTAL MEMBERS SHALL BE LOCATED ON THE |
| SWIMMING POOL SIDE OF THE FENCE. SPACING BETWEEN |
| VERTICAL MEMBERS SHALL NOT EXCEED 1 3/4 INCHES (44 MM) |
| IN WIDTH. WHERE THERE ARE DECORATIVE CUTOUTS WITHIN |
| VERTICAL MEMBERS, SPACING WITHIN THE CUTOUTS SHALL NOT |
| EXCEED 1 3/4 INCHES (44 MM) IN WIDTH. |
| R4501.17.1.7 |
| WHERE THE BARRIER IS COMPOSED OF DIAGONAL MEMBERS, THE |
| MAXIMUM OPENING FORMED BY THE DIAGONAL MEMBERS SHALL BE |
| NO MORE THAN 1 3/4 INCHES (44 MM). |
| R4501.17.1.8 |
| ACCESS GATES, WHEN PROVIDED, SHALL BE SELF-CLOSING AND |
| SHALL COMPLY WITH THE REQUIREMENTS OF SECTIONS |
| R4501.17.1.1 THROUGH R4501.17.1.7 AND SHALL BE EQUIPPED |
| WITH A SELF-LATCHING LOCKING DEVICE LOCATED ON THE POOL |
| SIDE OF THE GATE. WHERE THE DEVICE RELEASE IS LOCATED |
| NO LESS THAN 54 INCHES (1372 MM) FROM THE BOTTOM OF THE |
| GATE, THE DEVICE RELEASE MECHANISM MAY BE LOCATED ON |
| EITHER SIDE OF THE GATE AND SO PLACED THAT IT CANNOT BE |
| REACHED BY A YOUNG CHILD OVER THE TOP OR THROUGH ANY |
| OPENING OR GAP FROM THE OUTSIDE. GATES THAT PROVIDE |
| ACCESS TO THE SWIMMING POOL MUST OPEN OUTWARD AWAY FROM |
| THE POOL. THE GATES AND BARRIER SHALL HAVE NO OPENING |
| GREATER THAN 1/2 INCH (12.7 MM) WITHIN 18 INCHES (457 |