2020-03-10 12:51:32 | NEW TOWNHOUSE - | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) PLEASE SHOW ROOF SHEATHING TO BE TIGHT TO THE TOP OF | | THE FIRE RATED SEPARATION WALL (DRAWING S4.1 DETAIL | | R33B) PER FBC R302.2 EXCEPTION | | 2) PLEASE CLEARLY SHOW THAT THE WALL BETWEEN UNITS IS A | | 2HR FIRE RATED WALL. FBC R302.2 | | 3) PLEASE SHOW THE REQUIRED NAILING FOR THE META16 | | STRAPPING. | | 4) PLEASE PROVIDE A SITE PLAN/ CIVIL DRAWINGS SHOWING | | LOCATIONS, SETBACKS, FEMA FLOOD ZONE, FINISHED FLOOR | | ELEVATIONS ETC. | | 5) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | PRODUCT APPROVALS FOR THE WINDOWS, DOORS, OVERHEAD | | DOORS, ETC | | 6) PLEASE PROVIDE ROOFING SYSTEM PRODUCT APPROVALS | | (MIAMI DADE OR FLORIDA STATE) | | |
|