Plan Review Notes
Plan Review Notes For Permit 20020470
Permit Number 20020470
Review Stop P
Sequence Number 1
Notes
Date Text
2020-02-25 16:09:29PLUMBING COMMENTS: APPROVED WITH PROVISO
  
 PER WPB FBC 107.2.1 AND WPB FBC 107.3.4.1, PROVIDE AS A
 DEFERRED SUBMITTAL, A DETAIL SHOWING HOW THE ORIGINAL
 TUB BOX VOID AND THE NEW PIPE PENETRATION WILL BE
 FIRESAFED. IF EXISTING PIPING IS PVC THEN A UL ASSEMBLY
 SHALL BE SUBMITTED. IF EXISTING AND NEW PENETRATION ARE
 METAL THEN SUBMIT ON AN APPROVED FIRE RATED CONCRETE.
 SUBMITTAL SHALL BE SUBMITTED, APPROVED AND ON SITE
 PRIOR TO INSPECTION. PROCEED AT YOUR OWN RISK.
  
 THE FOLLOWING IS NOTED:
 NO RELOCATION OF FIXTURES. RISER DIAGRAMS ARE NOT
 REQUIRED.
 THE TUB IN THE MASTER BATH IS BEING REPLACED WITH A
 SHOWER STALL. THE NEW CONTROL VALVE IS BEING RELOCATED
 TO THE OPPOSITE WALL.
  