Date Text
2020-07-01 08:54:502017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20020426
 ADD: 4610 BROADWAY
 CONT: MASTER CONTRACTORS INC.
 TEL: 561-506-3627
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION.
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 3RD REVIEW
 DATE: WED. JULY 01/2020
 ACTION: DENIED
  
 1) 2ND REQUEST.PLEASE PROVIDE A SURVEY OF THE PROPERTY
 WHERE THE PROPOSED WORK IS TO OCCUR.
 2017 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATIVE CODE SECTION 107.3.5
 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. THE
 EXAMINATION OF THE DOCUMENTS BY
 THE BUILDING OFFICIAL SHALL INCLUDE THE FOLLOWING
 MINIMUM CRITERIA AND DOCUMENTS: SURVEY.
  
 2) 2ND REQUEST.THE SITE PLAN PROVIDED IN THIS SUBMITTAL
 PACKAGE SHOWS A BUILDING STRUCTURE ON THE LOT. THE
 CORNER LOT
 (PCN: 74-43-43-04-04-018-0170) IS CURRENTLY A VACANT
 LOT OWNED BY MIGUEL ROBLERO. THERE IS A SECOND VACANT
 LOT (PCN 74-43-43-0404-0018-0200) OWNED BY JOHN PETROU.
 A BUILDING IS LOCATED ON THE LOT ADDRESSED 4604
 BROADWAY ALSO OWNED BY JOHN PETROU. IT WOULD APPEAR THE
 PROPOSED PLAN SUBMITTED TO THE BUILDING DEPARTMENT
 COVERS 3 LOTS BY 2 DIFFERENT OWNERS, IS THIS CORRECT?
 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED.
  
 3) AS PER ZONING REQUEST SEPARATE PERMITS ARE REQUIRED
 FOR THE DUMPSTER ENCLOSURE AND STRIPPING OF THE PARKING
 LOT. NOT YET APPLIED FOR. 107.2.1.2. ADDITIONAL
 INFORMATION IS REQUIRED.
  
 4) 2ND REQUEST. SUBMITTED ALSO FOR THIS REVIEW IS AN 8
 ? X 11 INCH ACCESSIBLE PARKING DETAIL. PLEASE NOTE THIS
 IS DRAWN BY LARRY SCHNEIDER, AIA. PLEASE NOTE THIS
 DETAIL DOES NOT MEET THE SPACING OF THE WEST PALM BEACH
 MUNI CODE. SCHNEDIERS DETAIL SHOW 2 INCHES BETWEEN THE
 STRIPES!!!!!!!!!!!
 CITY ACCESSIBLE PARKING STANDARD. AN ACCESSIBLE PARKING
 SPACE AND ACCESS AISLE, PLEASE SEE THE 2017
 FBC-ACCESSIBILITY CODE 502.3.3 MARKING. ACCESS AISLES
 SHALL BE MARKED SO AS TO DISCOURAGE PARKING IN THEM.
 THE ACCESS AISLE MUST BE STRIPED DIAGONALLY TO
 DESIGNATE IT AS A NO-PARKING ZONE.
  
 ADVISORY 502.3.3 MARKING. THE METHOD AND COLOR OF
 MARKING ARE NOT SPECIFIED BY THESE REQUIREMENTS BUT MAY
 BE ADDRESSED BY STATE OR LOCAL LAWS OR REGULATIONS.
 BECAUSE THESE REQUIREMENTS PERMIT THE VAN ACCESS AISLE
 TO BE AS WIDE AS A PARKING SPACE, IT IS IMPORTANT THAT
 THE AISLE BE CLEARLY MARKED. FLORIDA
 LAW, S.553.5041(5)(C)1., REQUIRES DIAGONAL STRIPING OF
 ACCESS AISLES.
 THE CITY OF W. P. B. MUNI CODE ARTICLE XV 94-485
 PARKING PROVIDES A DOUBLE LINED DIMENSIONED PARKING
 STALL DETAIL.
  
 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, SFP & CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  