2020-03-03 10:52:03 | 2017 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 20020366 |
| ADD: 215 5TH ST. |
| CONT: THE PAVING LADY |
| TEL: 561-572-2600 |
| E-MAIL: [email protected] |
| |
| 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION. |
| |
| 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: TUES. MARCH 03/2020 |
| ACTION: DENIED |
| |
| 1) SURVEY SHOWS AREA TO BE REPAIRED IN RED LINE. |
| ASPHALT REPAIR, SEALCOAT AND RESTRIPE TO EXISTING AREA. |
| THE PLAN DOES SHOW 2 AREAS MARKED AS H/C SPACE BUT THE |
| PLAN ALSO SHOWS ALL PARKING SPACES AS SINGLE LINE |
| STRIPING. |
| PLEASE REVIEW THE CITY ACCESSIBLE PARKING STANDARD. AN |
| ACCESSIBLE PARKING SPACE AND ACCESS AISLE, PLEASE SEE |
| THE 2017 FBC-ACCESSIBILITY CODE 502.3.3 MARKING. ACCESS |
| AISLES SHALL BE MARKED SO AS TO DISCOURAGE PARKING IN |
| THEM. THE ACCESS AISLE MUST BE STRIPED DIAGONALLY TO |
| DESIGNATE IT AS A NO-PARKING ZONE. |
| |
| ADVISORY 502.3.3 MARKING. THE METHOD AND COLOR OF |
| MARKING ARE NOT SPECIFIED BY THESE REQUIREMENTS BUT MAY |
| BE ADDRESSED BY STATE OR LOCAL LAWS OR REGULATIONS. |
| BECAUSE THESE REQUIREMENTS PERMIT THE VAN ACCESS AISLE |
| TO BE AS WIDE AS A PARKING SPACE, IT IS IMPORTANT THAT |
| THE AISLE BE CLEARLY MARKED. FLORIDA |
| LAW, S.553.5041(5)(C)1., REQUIRES DIAGONAL STRIPING OF |
| ACCESS AISLES. |
| THE CITY OF W. P. B. MUNI CODE ARTICLE XV 94-485 |
| PARKING PROVIDES A DOUBLE LINED DIMENSIONED PARKING |
| STALL DETAIL. |
| |
| 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| JAMES A. WITMER BN, PX, SFP & CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |
| 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| TEL: 561-805-6717 |
| FAX: 561-805-6676 |
| |