2020-02-18 13:34:56 | 2017 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 20020258 |
| ADD: 5600 N. FLAGLER DR. SUITE: PH206 |
| CONT: WALL TO WALL WE DO IT ALL |
| TEL: 561-463-9708 |
| E-MAIL: [email protected] |
| |
| 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION. |
| |
| 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: TUES. FEB. 18TH/ 2020 |
| ACTION: DENIED |
| |
| 1) SHEET 1 PALM BEACH HOUSE FLOOR PLAN OF UNIT NOT TO |
| SCALE, SMALLER THAN 1/8 INCH SCALE. 2017 WEST PALM |
| BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER |
| 1 ADMINISTRATIVE CODE 107.2.1.3 QUALITY OF BUILDING |
| PLANS. BUILDING PLANS SHALL BE DRAWN TO A MINIMUM 1/8 |
| INCH SCALE UPON SUBSTANTIAL PAPER. THE BUILDING |
| OFFICIAL MAY ESTABLISH THROUGH DEPARTMENTAL POLICY, |
| OTHER STANDARDS FOR PLANS AND SPECIFICATIONS, IN ORDER |
| TO PROVIDE CONFORMITY TO ITS RECORD RETENTION PROGRAM. |
| |
| 2) 107.3.4.3 CERTIFICATION BY CONTRACTOR. PLEASE NOTE |
| THE EXCEPTION TO ENGINEERED PLANS UNDER 471.003(H) |
| ELECTRICAL/ PLUMBING/ MECHANICAL, 481.229(1)(C) |
| (BUILDING) REQUIRES THE CONTRACTOR FOR THAT TRADE THAT |
| WILL BE LICENSED IN THAT TRADE, WILL ALSO BE THE |
| CONTRACTOR THAT DESIGNS THE SYSTEM UNDER THAT TRADE. |
| FOR EACH TRADE THE CONTRACTOR RESPONSIBLE FOR THE |
| DESIGN UNDER THE TRADE LICENSED IN MUST PRINT THEIR |
| NAME, SIGN THEIR NAME AND LICENSE NUMBER, NOTE THESE |
| PLANS APPEAR TO BE DRAWN BY ONE INDUVIAL, THEY WOULD |
| HAVE TO BE LICENSED AS A BUILDING, ELECTRICAL AND |
| PLUMBING CONTRACTOR TO SUBMIT ALL THESE TRADES UNDER |
| ONE SHEET. |
| |
| 3) 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED. THE |
| PERMIT APPLICATION UNDER THE DESCRIPTION OF WORK |
| INDICATES INSTALL TILE, DRYWALL, PART. PLEASE PROVIDE A |
| BETTER DESCRIPTION OF WORK. SHEET 2 OF 3 IT WOULD |
| APPEAR THERE IS STILL A TUB IN THE BATHROOM BUT SHEET 3 |
| OF 3 IT WOULD APPEAR THE TUB HAS BEEN REMOVED AND A NEW |
| SHOWER, (5 INCH CURB) IS BEING PROPOSED. |
| |
| 4) FOR NEW SUB-SURFACES/ BASE FOR TILE MUST SHOW |
| COMPLIANCE WITH 2509.2 OF THE 2017 FBC-B: |
| GLASS MAT GYPSUM BACKING PANEL ASTM C1178 |
| NONASBESTOS FIBER-CEMENT BACKER BOARD ASTM C1288 OR ISO |
| 8336 CATEGORY C |
| NONASBESTOS FIBER-MAT REINFORCED CEMENTITIOUS BACKER |
| UNIT ASTM C1325 |
| |
| 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |
| A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE |
| THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED |
| DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE |
| MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS |
| AND INFORMATION LACKING UNDER THE PRIOR REVIEW. |
| |
| JAMES A. WITMER BN, PX, CBO |