2020-04-20 07:23:38 | 2ND REVIEW FBC-2017 RESIDENTIAL GAS |
| PERMIT #20020232 |
| 4/20/2020 |
| |
| CODES IN EFFECT: |
| |
| FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH |
| EDITION 2017 |
| FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 |
| FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 201 |
| FS- FLORIDA STATUTES |
| FAC- FLORIDA ADMINISTRATIVE CODE |
| WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH |
| EDITION 2017 |
| |
| PLAN REVIEW RESULTS: DENIED. |
| |
| 1) SHEETS P1: NOTE #4 & 10 INDICATE THE GAS WATER |
| HEATER ON THE EXTERIOR OF BUILDING HOWEVER THE PLAN |
| SHOWS THE WATER HEATER INSIDE THE UTILITY ROOM. A |
| THOROUGH REVIEW OF THE PLANS CANNOT BE COMPLETED AT |
| THIS TIME UNTIL THE EXACT LOCATION OF THE WATER HEATER |
| IS CLARIFIED- SECTION 107.2.1 WPB. |
| |
| 2) SHEETS A0 & P1: THE GAS ISOMETRIC DOES NOT APPEAR TO |
| CORRESPOND WITH THE LOCATION OF THE METER ON THE SITE |
| PLAN- SECTION 107.2.1 WPB. |
| |
| 3) P1. GAS ISOMETRIC: PROVIDE THE TOTAL DEVELOPED |
| LENGTH OF THE GAS PIPING RUN FROM THE POINT OF DELIVERY |
| TO THE MOST REMOTE OUTLET- SECTIONS G2413.3 AND G2513.4 |
| FBC RES. |
| |
| 4) P1. GAS ISOMETRIC: INDICATE WHICH TABLE FROM THE FBC |
| RES WAS USED TO SIZE THE GAS PIPING. PLEASE REFER TO |
| TABLES G2413.4(1) THROUGH G2413.4(21). |
| |
| 5) PROVIDE AN EQUIPMENT SCHEDULE FOR THE WATER HEATER |
| ON THE PLAN AND SUBMIT MANUFACTURER'S SPECIFICATIONS. |
| PLEASE NOTE THAT A THOUGH REVIEW OF THE WATER HEATER |
| INSTALLATION, GAS PIPING PLAN, AND COMBUSTION AIR AND |
| VENTING OF THE APPLIANCE CANNOT BE COMPLETED AT THIS |
| TIME. |
| |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. |
| |