Plan Review Notes
Plan Review Notes For Permit 20020214
Permit Number 20020214
Review Stop B
Sequence Number 1
Notes
Date Text
2020-02-10 09:36:27RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- ROOF TILE FLORIDA PRODUCT APPROVAL FL17152-R3 AND
 ROOF TILE ADHESIVE FLORIDA PRODUCT APPROVAL FL6332-R8
 SUBMITTED: CLEARLY MARK ADHESIVE PADDY SIZE AS REQUIRED
 BY CITY POLICY FOR ALL ROOFING PERMITS TO VERIFY
 COMPLIANCE WITH THE DESIGN PRESSURES OF SEC R301.2.1
 FBC-RESIDENTIAL.
  
 2- ROOFING UNDERLAYMENT TU PLUS-MAX FLORIDA PRODUCT
 APPROVALS FL5259-R29 SUBMITTED:
 CLEARLY MARK WHICH MAXIMUM DESIGN PRESSURES ASSEMBLY
 FROM SEC. 5.6.1 OF PRODUCT APPROVAL IS GOING TO BE
 USED. OR IF USING THE FRSA/TRI APRIL 2012 (04-12)
 REVISED EDITION, THEN PROVIDE COMPLETE INFORMATION
 SHOWING THE DETERMINATION OF DESIGN WIND LOADS AND
 UNDERLAYMENT FASTENING AS REQUIRED BY SEC. 5.6.1 OF
 PRODUCT APPROVAL SUBMITTED.
  
 3- IT IS NOT CLEAR WHY SUBMITTING FLAT ROOF FLORIDA
 PRODUCT APPROVAL FL16709-R6. COVER PAGE STATES "PG 3 OF
 4 MODIFIED FOR THE UNDERLAYMENT ONLY". IS THIS THE
 UNDERLAYMENT FOR THE TILE ROOF?. IF SO, THIS IS A FLAT
 ROOF ASSEMBLY NOT AN UNDERLAYMENT FOR ROOF TILE. THE
 UNDERLAYMENT FOR THE ROOF TILE IS THE TU PLUS PRODUCT
 APPROVAL SUBMITTED. SEC. 107.2.1 CITY AMENDMNTS.
  
 ON THE OTHER HAND, IF THERE IS A FLAT ROOF IN THIS ROOF
 , THEN CLEARLY MARK WHICH APPROVED ASSEMBLY IS GOING TO
 BE INSTALLED TO VERIFY COMPLIANCE WITH THE DESIGN
 PRESSURES OF SEC. R301.2.1 FBC-RESIDENTIAL.
  
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  