Plan Review Notes
Plan Review Notes For Permit 20020119
Permit Number 20020119
Review Stop Z
Sequence Number 1
Notes
Date Text
2020-03-18 14:56:29FAILED
  
 PROVIDE WRITTEN RESPONSES TO COMMENTS.
  
 1) THIS SIGN IS BEING CLASSIFIED AS SIGN #2 FOR H&M.
 NOTE: THE ROSEMARY SQUARE TENANT SIGN CRITERIA ONLY
 PERMIT ONE ARCADE IDENTITY SIGN PER FRONTAGE, SO THIS
 SIGN IS NOT PERMITTED UNDER THE CURRENT REGULATIONS.
  
 2) THE PROPOSED SIGN DOES NOT MATCH ONE OF THE ARCADE
 IDENTITY SIGN TYPES INCLUDED IN THE ROSEMARY SQUARE
 TENANT SIGN CRITERIA. THE PERMISSIBLE MOUNTING OPTIONS
 THAT ARE SIMILAR TO THE PROPOSED SIGN ARE SUSPENDED
 LETTERS ON A RACEWAY (WHICH WOULD BE THE FRONT OF THE
 SUPPORT FRAME, WITH NO BACK PANEL) OR TENANT NAME
 MOUNTED TO A SUSPENDED PANEL (WHICH WOULD REQUIRE THE
 SUPPORT FRAME TO CONNECT TO THE TOP OF THE BACK PANEL).
  
 3) H&M CURRENTLY HAS 6 WALL MOUNTED SIGNS. PROVIDE THE
 DEMOLITION PERMIT FOR THESE 6 SIGNS AS THEY ARE NOT
 PERMITTED TO REMAIN ONCE THE SIGN(S) COMPLYING WITH THE
 NEW ROSEMARY SQUARE TENANT SIGN CRITERIA ARE INSTALLED.
  
 THE FOLLOWING COMMENTS DEAL WITH SPECIFIC DESIGN
 ELEMENTS; HOWEVER THEY MAY CHANGE BASED ON ADDRESSING
 COMMENT #2 ABOVE.
  
 4) THE EAST ELEVATION SHEET LISTS THE DISTANCE OF THE
 SIGN ABOVE GRADE AS 10 FEET; HOWEVER THE SIGN DETAILS
 LIST THE SIGNS AS BEING 9.5 FEET ABOVE GRADE. ALL PLANS
 NEED TO SHOW THE SAME CONDITIONS. NOTE: 9 FEET IS THE
 MINIMUM REQUIRED CLEARANCE, SO EITHER HEIGHT MEETS THE
 ROSEMARY SQUARE TENANT SIGN CRITERIA.
  
 5) THE ELEVATION TYPICAL SHEET NEEDS TO SHOW THE
 OPENING IN WHICH THE PROPOSED SIGN IS TO BE LOCATED,
 NOT A GENERIC OPENING OR THE OPENING FOR A DIFFERENT
 SIGN (IN THIS CASE THE ONE UNDER PERMIT 20020115). THE
 OPENING WIDTH NEEDS TO BE PROVIDED SO STAFF CAN VERIFY
 THAT THE SIGN MEETS THE MAXIMUM WIDTH REQUIREMENT.
 ADDITIONALLY, THE ROSEMARY SQUARE TENANT SIGN CRITERIA
 LIMIT THE MAXIMUM HEIGHT OF ARCADE SIGNS AT 12 FEET
 FROM THE FINISHED FLOOR. THE "ELEVATION TYPICAL" SHEET
 NEEDS TO INCLUDE THE DIMENSION TO THE TOP OF THE BACK
 PLATE TO VERIFY THAT IT DOES NOT EXCEED THE 12 FOOT
 HEIGHT LIMIT.
  
 6) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE THE
 BACK PLATE TO BE COUNTED WITHIN THE SIGN SQUARE
 FOOTAGE. BASED ON THE DIMENSIONS PROVIDED, THE SIGN IS
 4.74 SF IN AREA.
  
 7) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE
 THAT THE SIGN COPY AREA SHALL MAINTAIN A MARGIN AT
 LEAST SIX INCHES FROM ANY EDGE OF THE PERCEIVED SIGN
 AREA. THE FRAME ELEMENTS THAT HANG THE SIGN TO THE ARCH
 ARE THE PERCEIVED SIGN AREA. PROVIDE VERIFICATION
 DIMENSIONS TO SHOW THAT THE FURTHEST PROJECTION OF THE
 SIGN (WHICH INCLUDES THE BACK PLATE) IS A MINIMUM OF 6
 INCHES FROM THE SUPPORT TUBES.
  
 8) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE
 THAT THE LOCATION OF ALL OPENINGS FOR CONDUIT SLEEVES
 AND SUPPORT IN SIGN PANELS AND BUILDING WALLS BE
 INDICATED BY THE SIGN CONTRACTOR IN THE SHOP DRAWINGS.
 STAFF NEEDS TO SEE THESE AS PART OF THE PERMIT TO
 VERIFY THAT THE SIGN'S ELECTRICAL CONNECTIONS ARE NOT
 VISIBLE TO THE PUBLIC.
  
 SIGN SF
  
 PERMITTED: 140 SF
 SIGN #1 (PERMIT 20020115): 4.74 SF
 SIGN #2 (PERMIT 20020119): 4.74 SF (CURRENTLY NOT
 PERMITTED)
  
 TOTAL PROPOSED: 9.48 SF
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved