Date |
Text |
2020-03-18 14:37:11 | FAILED |
| |
| PROVIDE WRITTEN RESPONSES TO COMMENTS. |
| |
| 1) THIS SIGN IS BEING CLASSIFIED AS SIGN #1 FOR H&M. |
| NOTE: THE ROSEMARY SQUARE TENANT SIGN CRITERIA ONLY |
| PERMIT ONE ARCADE IDENTITY SIGN PER FRONTAGE. |
| |
| 2) HE PROPOSED SIGN DOES NOT MATCH ONE OF THE ARCADE |
| IDENTITY SIGN TYPES INCLUDED IN THE ROSEMARY SQUARE |
| TENANT SIGN CRITERIA. THE PERMISSIBLE MOUNTING OPTIONS |
| THAT ARE SIMILAR TO THE PROPOSED SIGN ARE SUSPENDED |
| LETTERS ON A RACEWAY (WHICH WOULD BE THE FRONT OF THE |
| SUPPORT FRAME, WITH NO BACK PANEL) OR TENANT NAME |
| MOUNTED TO A SUSPENDED PANEL (WHICH WOULD REQUIRE THE |
| SUPPORT FRAME TO CONNECT TO THE TOP OF THE BACK PANEL). |
| |
| 3) H&M CURRENTLY HAS 6 WALL MOUNTED SIGNS. PROVIDE THE |
| DEMOLITION PERMIT FOR THESE 6 SIGNS AS THEY ARE NOT |
| PERMITTED TO REMAIN ONCE THE SIGN(S) COMPLYING WITH THE |
| NEW ROSEMARY SQUARE TENANT SIGN CRITERIA ARE INSTALLED. |
| |
| 4) THE FOLLOWING COMMENTS DEAL WITH SPECIFIC DESIGN |
| ELEMENTS; HOWEVER THEY MAY CHANGE BASED ON ADDRESSING |
| COMMENT #2 ABOVE. |
| |
| 5) THE EAST ELEVATION SHEET LISTS THE DISTANCE OF THE |
| SIGN ABOVE GRADE AS 10 FEET; HOWEVER THE SIGN DETAILS |
| LIST THE SIGNS AS BEING 9.5 FEET ABOVE GRADE. ALL PLANS |
| NEED TO SHOW THE SAME CONDITIONS. NOTE: 9 FEET IS THE |
| MINIMUM REQUIRED CLEARANCE, SO EITHER HEIGHT MEETS THE |
| ROSEMARY SQUARE TENANT SIGN CRITERIA. |
| |
| 6) THE ROSEMARY SQUARE TENANT SIGN CRITERIA LIMIT THE |
| MAXIMUM HEIGHT OF ARCADE SIGNS AT 12 FEET FROM THE |
| FINISHED FLOOR. THE "ELEVATION TYPICAL" SHEET NEEDS TO |
| INCLUDE THE DIMENSION TO THE TOP OF THE BACK PLATE TO |
| VERIFY THAT IT DOES NOT EXCEED THE 12 FOOT HEIGHT |
| LIMIT. |
| |
| 7) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE THE |
| BACK PLATE TO BE COUNTED WITHIN THE SIGN SQUARE |
| FOOTAGE. BASED ON THE DIMENSIONS PROVIDED, THE SIGN IS |
| 4.74 SF IN AREA. |
| |
| 8) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE |
| THAT THE SIGN COPY AREA SHALL MAINTAIN A MARGIN AT |
| LEAST SIX INCHES FROM ANY EDGE OF THE PERCEIVED SIGN |
| AREA. THE FRAME ELEMENTS THAT HANG THE SIGN TO THE ARCH |
| ARE THE PERCEIVED SIGN AREA. PROVIDE VERIFICATION |
| DIMENSIONS TO SHOW THAT THE FURTHEST PROJECTION OF THE |
| SIGN (WHICH INCLUDES THE BACK PLATE) IS A MINIMUM OF 6 |
| INCHES FROM THE SUPPORT TUBES. |
| |
| 9) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE |
| THAT THE LOCATION OF ALL OPENINGS FOR CONDUIT SLEEVES |
| AND SUPPORT IN SIGN PANELS AND BUILDING WALLS BE |
| INDICATED BY THE SIGN CONTRACTOR IN THE SHOP DRAWINGS. |
| STAFF NEEDS TO SEE THESE AS PART OF THE PERMIT TO |
| VERIFY THAT THE SIGN'S ELECTRICAL CONNECTIONS ARE NOT |
| VISIBLE TO THE PUBLIC. |
| |
| SIGN SF |
| |
| PERMITTED: 140 SF |
| SIGN #1 (PERMIT 20020115): 4.74 SF |
| |