2020-02-12 16:54:19RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- ROOF TILE FL 7804-R10 SUBMITTED. CLEARLY SPECIFY
 TILE FASTENING METHOD AS REQUIRED BY CITY POLICY FOR
 ALL ROOFFING PERMITS TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R3012.1 FBC-RESIDENTIAL. IF
 SPECIFYING SCREWS, THEN SPECIFY THE NUMBER AND SIZE OF
 SCREWS TO BE USED FOR ALL ROOF ZONES. IF USING
 ADHESIVE, THEN PROVIDE PRODUCT APPROVAL AND CLEARLY
 MARK PADDY SIZE.
 NOTE: KEEP IN MIND THAT THIS BUILDING IS LOCATED IN
 WIND EXPOSURE D. PROPOSED FASTENING NEEDS TO MEET THE
 REQUIRED ROOF TILE RESISTANCE VALUE FOR ALL ROOF ZONES
 BASED ON THE BUILDING EXPOSURE AND BUILDING HEIGHT.
 PROVIDE INFORMATION SHOWING THE ROOF TILE RESISTANCE
 VALUE ON ALL ROOF ZONES.
  
 IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE
 TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE
 COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]