2020-03-12 11:45:42CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 2ND REVIEW
 PLUMBING COMMENTS: DENIED
 1. PER WPB FBC 107.2.1, SHOW LOCATION OF EXISTING STACK
 THAT WASHER DRYER IS TO BE CONNECTED TO. PROVIDE A
 SANITARY RISER DIAGRAM SHOWING HOW KEYNOTE #7 ON PLAN
 PAGE A2.2 WILL BE ACCOMPLISHED. IF THIS IS A SINGLE
 PIPE STACK (WASTE STACK VENT AS DESCRIBED IN FBC PL
 913), IT SHALL NOT BE OFFSET. PLEASE REFER TO THE
 PROVISIONS OF FBC PL 905, 909 AND 913 FOR GUIDANCE.
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  