2020-02-11 13:50:55 | BUILDING REVIEW COMMENTS |
| CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| |
| 1- ADDRESS OF PROJECT SHOWN ON ALL PLANS IS INCORRECT. |
| THE CORRECT ADDRESS IS 610 CLEMATIS ST. NOT 601. REVISE |
| AS REQUIRED. NOTE: COVER SHEET HAS 4 PLACES LISTING THE |
| INCORRECT ADDRESS. PLEASE MAKE SURE ALL THE INFORMATION |
| IS CORRECTED. SEC. 107.2.1 CITY AMENDMENTS. |
| |
| 2- ONLY ONE SET OF PLANS WAS SIGNED AND SEALED BY THE |
| ARCHITECT OF RECORD. THE OTHER COPY WAS NOT SIGNED AND |
| SEALED. BOTH COPIES NEED TO BE SIGNED AND SEALED |
| (ORIGINAL SEAL AND SIGNATURE) SEC. 107.1 CITY |
| AMENDMENTS. CHAPTER 481 FLORIDA STATUTES. |
| |
| 3- INFORMATION ABOUT SPRINKLER HEADS IS NOT CLEAR. SEC. |
| 107.2.1 CITY AMENDMENTS. KEY NOTE #8 ON THE DEMOLITION |
| PLAN ON SHEET A2.1 CALLS FOR REMOVAL AND CAPPING OF |
| EXISTING SIDEWALL SPRINKLER HEAD AND SUPPLY LINE. ON |
| THE OTHER HAND, KEY NOTE #11ON THE NEW FLOOR PLAN ON |
| SHEET A2.2 CALLS TO VERIFY IF EXISTING SPRINKLER HEAD |
| WILL COVER THE NEW EXPOSED AREA. CLEARLY SPECIFY |
| PROPOSED ALTERATION TO THE SPRINKLER SYSTEM. NOTE: |
| SEPARATE PERMIT WILL BE REQUIRED. |
| |
| 4-FLOORING SOUND INSULATION MATERIAL FOR NEW TILE: |
| |
| A) PROVIDE 2 COPIES OF THE FLAME SPREAD INDEX AND SMOKE |
| DEVELOPED INDEX TEST DONE IN ACCORDANCE WITH ASTM E 84 |
| OR UL 723 AS REQUIRED BY SEC. 720.1 OF FBC 6TH EDITION |
| (2017). |
| |
| B) PROVIDE 2 COPIES OF THE SOUND TRANSMISSION CLASS |
| (STC) TEST DONE IN ACCORDANCE WITH ASTM E 90 AS |
| REQUIRED BY SEC. 1207.2 OF FBC 6TH EDITION (2017). |
| |
| C) PROVIDE 2 COPIES OF THE IMPACT INSULATION CLASS |
| (IIC) TEST DONE IN ACCORDANCE WITH ASTM E 492 AS |
| REQUIRED BY SEC. 1207.3 OF FBC 6TH EDITION (2017). |
| |
| NOTE: TEST SAMPLES TO MATCH BUILDING FLOOR/CEILING |
| CONSTRUCTION AND PROPOSED FLOOR FINISH. ALSO, THERE ARE |
| TESTS FOR 6" OR 8" CONCRETE SLABS WITH OR WITHOUT |
| ACOUSTICAL CEILING. TYPICALLY THERE ARE NOT SUSPENDED |
| ACOUSTICAL CEILINGS IN THESE BUILDINGS. |
| |
| 5- VALUATION DECLARED IN THE PERMIT APPLICATION IS LOW. |
| VALUATION TO INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S |
| OVERHEAD AND PROFIT AND DESIGN PROFESSIONAL FEES AS |
| REQUIRED BY SEC. 109.3 CITY AMENDMENTS. UPDATE |
| VALUATION TO INCLUDE ALL COSTS OR PROVIDE COPY OF |
| SIGNED CONTRACTS INCLUDING DESIGN PROFESSIONAL FEES. |
| |
| |