2020-02-04 10:27:23NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW
 COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR
 TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME
 OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT
 ISSUANCE.
  
 ****IF PROVISO OPTION IS SELECTED, THEN NEED THE ENRGY
 CALCULATIONS SIGNED BY THE OWNER PRIOR TO PERMIT
 ISSUANCE.
  
  
  
 1- ENERGY CALCULATIONS SUBMITTED:
 A)THE ENERGY FORM SUBMITTED DOESN'T SEEM TO BE SIGNED
 BY THE OWNER OF THIS BUILDING. THE OWNER'S SIGNATURE
 SHOWN ON THE PERMIT APPLICATION AND THE SIGNATURE SHOWN
 ON THE ENERGY CALCULATIONS DON'T MATCH. CLARIFY WHY.
 NOTE: ONLY THE OWNER, ARCHITECT OR LEGAL AGENT IS
 AUTHORIZED TO SIGN THIS FORM AS REQUIRED BY SEC.
 R103.1.1.2 FBC-ENERGY CONSERVATION, 6TH EDITION (2017).
  
 B) PROVIDE COMPLETE AND CORRECT INFORMATION ON TOP OF
 FORM. PROVIDE CORRECT OWNER'S AND BUILDER'S NAME.
 PROVIDE COMPLETE ADDRESS OF THIS HOUSE. PROVIDE THE
 PERMIT OFFICE.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 C) WALL INFORMATION ON ITEM 9 ON PAGE 1 OF 4 IS MISSING
 THE INFORMATION FOR THE ADJACENT WALL BY THE GARAGE
 AREA. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 D) REVISE THE ATTIC VENT RATIO ON PAGE 2 OF 5. THE
 RATIO IS 1/150 NOT 1/300. SEC. R806.2 FBC-RESIDENTIAL.
 OR, PERSON PREPARING THE ENERGY CALCULATIONS TO PROVIDE
 COMPLETE DOCUMENTATION SHOWING COMPLIANCE WITH THE
 1/300 RATIO AS REQUIRED BY THE EXCEPTION ON SEC.
 R806.2.
  
 E) BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL
 (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY
 CONSERVATION.
  
 2- DRAWING C-1 (SITE/DRAINAGE PLAN):
 DRAWING SUBMITTED HAVE A COPY OF A DIGITAL SIGNATURE.
 PERMIT APPLICATION AND PLANS ARE NOT ELECTRONICALLY
 SUBMITTED. PLANS NEED TO HAVE THE ORIGINAL SEAL AND
 SIGNATURE OF THE ENGINEER OF RECORD AS REQUIRED BY SEC.
 61G15-23.003 FAC AND CHAPTER 471 F.S. WHEN SUBMITTING
 PLANS/DOCUMENTS FOR PUBLIC RECORDS.
  
 3- THERE IS A DISCREPANCY BETWEEN THE FOOTING SIZE
 RECOMMENDED BY THE SOIL TEST ENGINEER AND THE FOOTING
 SIZE SPECIFIED ON PLANS. DESIGNER OF RECORD TO REVIEW
 SOIL TEST REPORT RECOMMENDATIONS AND EITHER CHANGE THE
 FOOTING SIZE FOLLOWING THE ENGINEER'S RECOMMENDATIONS
 OR PROVIDE DOCUMENTATION SHOWING THAT THE PROPOSED
 FOOTING SIZE IS ADEQUATE. SEC. 107.2.1 CITY AMENDMENTS.
  
 4- SOIL TEST REPORT SUBMITTED HAVE A COPY OF THE
 ENGINEER'S SIGNATURE. PROVIDE REPORT WITH ENGINEER'S
 ORIGINAL SEAL AND SIGNATURE (2 COPIES) AS REQUIRED BY
 CHAPTER 471 F.S. WHEN SUBMITTING DOCUMENTS FOR PUBLIC
 RECORDS.
  
 5- REVISE ATTIC ACCESS DETAIL ON SHEET A-1. THE MIN.
 DIMENSION IS 22" AS REQUIRED BY SEC. R807.1
 FBC-RESIDENTIAL.
  
 6- REVISE SPECS FOR GARAGE DOOR LEADING TO THE
 RESIDENCE. IF THE DOOR IS NOT SOLID, THEN IT NEEDS TO
 BE HONEYCOMB CORE STEEL DOOR NOT METAL CLADD DOOR. OR
 20 MINUTE FIRE RATED DOOR. SEC. R302.5.1
 FBC-RESIDENTIAL. REVISE DOOR SCHEDULE SPECS ON SHEET
 A-1.
  
 7- REVISE THE SIZE OF THE STRUCTURAL BUCK SPECIFIED ON
 DETAIL C ON SHEET A-2. STRUCTURAL BUCK NEEDS TO PROVIDE
 FULL SUPPORT TO THE DOOR FRAME AND NEED TO EXTEND
 BEYOND THE INTERIOR FACE OF THE WINDOW OR DOOR FRAME AS
 REQUIRED BY SEC. R609.7.2.1 FBC-RESIDENTIAL. 2X4 BUCK
 IS SMALLER THAN THE DOOR FRAME. REVISE AS REQUIRED.
  
 8- WALL ENTRY SECTION #3 ON SHEET A-3:
 A) NEED TO SPECIFY 2 LAYERS OF WATER RESISTIVE BARRIERS
 AS REQUIRED BY SEC. R703.7.3 FBC-RESIDENTIAL ON THE
 WOOD FRAMED WALL.
  
 B) NEED TO SPECIFY THE 7/8" MIN. STUCCO THICKNESS AS
 REQUIRED BY TABLE R702.1(1) FBC-RESIDENTIAL.
  
 9- VALUATION DECLARED IN THE PERMIT APPLICATION IS LOW.
 VALUATION TO INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S
 OVERHEAD AND PROFIT AND DESIGN PROFESSIONAL FEES AS
 REQUIRED BY SEC. 109.3 CITY AMENDMENTS. VALUATION WAS
 UPDATED TO $204,585. THE PERMIT FEE BALANCE IS $4718.42
 (INCLUDES PLAN REVIEW EXPEDITED FEE).
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. (NOTE: SUBMIT OLD DRAWINGS FOR REFERENCE). A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  