Date |
Text |
2020-02-03 14:05:38 | 2017 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 20010804 |
| ADD: 4801 DREHER TRAIL N |
| CONT: GAST CONSTRUCTION GROUP |
| TEL: 561-329-4038 |
| E-MAIL: [email protected] |
| |
| 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION. |
| |
| 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: MON. FEB. 03/2020 |
| ACTION: DENIED |
| |
| 1) THE SHEET HP-1 SHOWS A PROPOSED EXTENSION OF PAVER |
| WALKWAYS. WHAT IS NOT CLEAR WITH THE PAVER DETAIL FOR |
| THE DECK-O-DRAIN IS THE DECK-O-DRAIN PART OF THE |
| EXISTING SPLASH PAD (INTERACTIVE WATER FEATURE)? |
| IS THE 5 FEET WIDE PAVER WALK WAY TO BE PART OF THE IWF |
| WET DECK? AND IF SO SLOPED WHICH WAY? 2017 FBC-B |
| SECTION 454.1.9.8.6.10. |
| |
| 2) THE NEW PAVER WALKWAYS DO NOT INDICATE ANY CHANGE IN |
| GRADE NOR IF THERE IS A CROSS SLOPE, PLEASE SHOW |
| COMPLIANCE WITH THE 2017 FBC-ACCESSIBILITY CODE SECTION |
| 403.3. SLOPE. THE RUNNING SLOPE OF WALKING SURFACES |
| SHALL NOT BE STEEPER THAN 1:20. THE CROSS SLOPE OF |
| WALKING SURFACES SHALL NOT BE STEEPER THAN 1:48. PLEASE |
| INDICATE HOW COMPLIANCE WILL BE ACHIEVED. |
| |
| A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| JAMES A. WITMER BN, PX, CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |
| 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| TEL: 561-805-6717 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |