Plan Review Notes For Permit 20010577 |
Permit Number |
20010577 |
|
Review Stop |
B |
Sequence Number |
3 |
|
Notes |
Date |
Text |
2020-03-26 10:28:43 | BUILDING REVIEW APPROVED WITH PROVISO: | | 1- TRUSS PACKAGE: TRUSS ENGINEER TO REVISE LIVE AND | | DEAD LOADS DESIGN CRITERIA TO MATCH DESIGN CRITERIA | | SPECIFIED BY THE ARCHITECT OF RECORD ON "ROOF FRAMING | | NOTES" ON SHEET S-1. | | NOTE: REVISE TRUSS PACKAGE AND SUBMIT REVISED TRUSS | | PACKAGE TO INSPECTOR AT FRAMING INSPECTION. |
|