Plan Review Notes
Plan Review Notes For Permit 20010423
Permit Number 20010423
Review Stop Z
Sequence Number 5
Notes
Date Text
2021-03-30 13:12:58FAILED
  
 PROVIDE WRITTEN RESPONSES TO COMMENTS.
  
 ARCADE IDENTITY SIGN TYPE 1D
  
 PERMITTED: 97.5 SF
 EXISTING AWING SIGNS (3): 6.03 SF
 APPROVED BARRIO SANGRIA SIGN (PERMIT 19050032): 16.8 SF
 PROPOSED SIGN: 23 SF
  
 TOTAL SIGN AREA: 45.83 SF
  
 1) REPEAT COMMENT: THE ROSEMARY SQUARE TENANT SIGN
 CRITERIA REQUIRE ALL LIGHTING CONDUIT, WIRING, BALLAST
 BOXES, TRANSFORMERS, AND OTHER EQUIPMENT NECESSARY FOR
 SIGN CONNECTION SHALL BE CONCEALED AND NOT VISIBLE TO
 THE PUBLIC. THE PROPOSED SIGN LIGHTING HAS AN EXPOSED
 BELL BOX WITH DISCONNECT SWITCH AND ELECTRICAL LEAD
 WITHIN FLEXIBLE CONDUIT, WHICH IS NOT PERMITTED.
 ADDITIONALLY, NO INFORMATION IS PROVIDED AS TO HOW THE
 ELECTRIC SERVICE IS PROVIDED TO THE BELL BOX. YOU ARE
 SHOWING THE LIGHTING AS PART OF THIS PERMIT, SO IN
 ACCORDANCE WITH THE ROSEMARY SQUARE TENANT SIGN
 CRITERIA YOU NEED TO PROVIDE THE INFORMATION ON HOW THE
 CONCEALMENT REQUIREMENT IS MET. YOU ARE NOT ALLOWED TO
 DESIGN A SIGN WITH THE WIRING STUBBED OUT THAT THEN
 REQUIRES NON-COMPLIANCE WITH THE CONCEALMENT
 REQUIREMENT. IN THIS SPECIFIC CASE YOU MAY NOT REMOVE
 THE ITEMS WHICH DID NOT COMPLY WITH THE ROSEMARY SQUARE
 TENANT SIGN CRITERIA AND SIMPLY STATE IT WILL BE
 PROVIDED WITH OTHERS. YOU NEED TO COORDINATE WITH THE
 "OTHERS" WHO ARE PROVIDING THE ELECTRICAL PRIMARY AND
 PROVIDE THIS INFORMATION ON THE PLANS TO VERIFY THAT
 THE CONCEALMENT REQUIREMENTS ARE MET. THE PERMIT NUMBER
 CITED (20061298) IN THE RESPONSE DOES NOT SHOW ANY
 ELECTRICAL CONNECTION TO THE PROPOSED LOCATION OF THIS
 SIGN. YOU ARE REQUIRED TO SHOW HOW THE ELECTRICAL TO
 THE LIGHTING FOR THIS SIGN COMPLIES WITH THE ROSEMARY
 SQUARE TENANT SIGN CRITERIA. ***** THE RESPONSE STATES
 THAT THE SIGN PERMIT WILL NOT BE DOING ELECTRICAL WORK
 AND THAT NO ELECTRICAL PERMIT WAS PULLED; HOWEVER, YOU
 DID SUBMIT AN ELECTRICAL SUB PERMIT FOR THIS
 INSTALLATION (PERMIT NUMBER 20010423). SINCE YOU HAVE
 SUBMITTED AN ELECTRICAL SUB PERMIT FOR YOUR SIGN THAT
 PROPOSES ELECTRIC, IN ACCORDANCE WITH THE ROSEMARY
 SQUARE TENANT SIGN CRITERIA YOU NEED TO PROVIDE
 DRAWINGS SHOWING THAT THE ELECTRIC MEETS THE REQUIRED
 STANDARDS (AS REPEATED ON EACH PERMIT REVIEW). YOUR
 OTHER OPTION IS TO REMOVE ALL REFERENCE TO ILLUMINATION
 AND ELECTRIC, TO INCLUDE THE "SATIN BLACK DIRECTIONAL
 BULLET SIGN LIGHTS" AND THE MOUNTING ARMS, FROM THE
 SIGN PERMIT. THESE WILL THEN ALL NEED TO BE SHOWN IN
 DETAIL ON THE ELECTRIC PERMIT. IF THE ELECTRIC PERMIT
 DOES NOT PASS, YOU WILL NOT BE PERMITTED TO INSTALL THE
 BULLET SIGN LIGHT.
  
 NOTE: THE SIGN WITH NO ELECTRIC DOES MEET THE ROSEMARY
 SQUARE TENANT SIGN CRITERIA.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected].
  