Plan Review Notes
Plan Review Notes For Permit 20010149
Permit Number 20010149
Review Stop G
Sequence Number 1
Notes
Date Text
2020-01-16 14:43:39CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 NFPA 58 = LIQUIFIED PETROLEUM GAS CODE
 NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017
 NFPA 99 = HEALTH CARE FACILITIES CODE
 NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 20010149 REVISION TO MASTER 18090722
  
 1ST REVIEW
 GAS COMMENTS: DENIED
  
 1.REFER TO GAS RISER DIAGRAM SUBMITTED BY APPLICANT;
 A.THE GAS SYSTEM WAS INITIALLY SUBMITTED IN 18090722
 PERMIT DOCUMENT PLAN SHEET S-9 WITH THE LONGEST RUN
 BEING 46 FEET. THE LONGEST RUN IS NOW STATED TO BE 80
 FEET. AS SUCH THE CSST EHD 19 TUBING BETWEEN THE
 TANKLESS WATER HEATER AND THE DRYER IS NOW UNDERSIZED.
 RESIZE BASED ON THE 80 FEET.
 B.THE RISER DIAGRAM IS UNCLEAR AS TO THE ROUTING OF THE
 HORIZONTAL DISTRIBUTION IN SIDE THE RESIDENCE. PLEASE
 CONFIRM ON THE DRAWING THAT IT IS ROUTED IN THE CRAWL
 SPACE AS IS INDICATED ON THE 18090722 PERMIT DOCUMENTS
 AND SHOW THE CORRECT LENGTH OF THE VERTICAL PORTION OF
 THE DRYER BRANCH AS THE DRYER ITSELF IS LOCATED ON THE
 SECOND FLOOR.
 C.CONCERNING THE ADDED RUN TO THE ADDED POOL HEATER,
 PROVIDE CUT LENGTHS OF GALVANIZED PIPING AT THE POOL
 HEATER, FROM THE METER TO THE TEE AT THE BRANCH TO THE
 POOL HEATER AND FROM THE TEE TO THE PE PIPING. PLEASE
 NOTE THAT YOU HAVE INDICATED 80 FEET OF UNDERGROUND PE
 TO THE POOL HEATER. IF THE 80 FEET STILL STANDS THEN
 YOU HAVE EXCEEDED THE 80 FEET LONGEST RUN AND SHALL
 CALCULATE BASED ON THE CORRECT MAXIMUM LENGTH. THIS
 APPLIES TO THE HOUSE INTERIOR PIPING AS WELL.
 D.TOTAL BTU IS STATED AS 729,000. I CALCULATE 729,200.
 PER WPB FBC 107.2.1, CLARIFY.
 E.PROVIDE PROJECT ADDRESS ON RISER DIAGRAM
  
 2.PER WPB FBC 107.2.1, PROVIDE ACCURATE TECHNICAL
 DATA/SPECIFICATION FOR POOL HEATER INDICATING ACTUAL
 MODEL NUMBER, BTUS, TYPE OF GAS APPLICATION, DIMENSIONS
 AQND MANUFACTURER?S INSTALLATION RECOMMENDATIONS. ALL
 INFORMATION SHALL BE CLEARLY LEGIBLE.
  
 3. REGARDING THE RESUBMITTAL, PROVIDE RISER DIAGRAM AND
 CALCULATIONS ON A LARGE ENOUGH SHEET OF PAPER TO
 ACCOMMODATE THE FOLLOWING PROVISOS
 A.REFER TO PERMIT 18090722 DOCUMENTS PLAN SHEET S-1.
 RECORD DRAWING SHALL BE PROVIDED DEPICTING ACTUAL
 MATERIAL, ROUTING AND SIZING OF GAS PIPE BENEATH THE
 CRAWL SPACES AND SHALL INCLUDE BRANCH TO DRYER ON
 SECOND FLOOR. DRAWING SHALL BE SUBMITTED, APPROVED AND
 ON SITE PRIOR TO FINAL INSPECTION.
 B.REFER TO PERMIT 18090722 DOCUMENTS PLAN SHEET S-9.
 RECORD DRAWING SHALL BE PROVIDED WITH VREVISED GAS
 RISER DIAGRAM TO INCLUDE GAS PIPING TO THE ADDED POOL
 HEATER AND ACCURATELY REFLECT THE BRANCH TO DRYER ON
 SECOND FLOOR WITH CORRECT VERTICAL LENGTH. DRAWING
 SHALL BE SUBMITTED, APPROVED AND ON SITE PRIOR TO FINAL
 INSPECTION.
 C.WPB FBC 107.2.1, RECORD SITE DRAWING SHALL BE
 PROVIDED DEPICTING ACTUAL MATERIAL, ROUTING AND SIZING
 OF GAS PIPE FROM REGULATOR/METER TO POOL HEATER. SHOW
 LOCATIONS OF METER AND POOL HEATER. DRAWING SHALL BE
 SUBMITTED, APPROVED AND ON SITE PRIOR TO FINAL
 INSPECTION.
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 20010149 REV TO MASTER 18090722
  
 134 GREYNOR DR
  
  
  
  