Plan Review Notes
Plan Review Notes For Permit 19120578
Permit Number 19120578
Review Stop P
Sequence Number 2
Notes
Date Text
2020-02-06 13:33:09PLUMBING COMMENTS: APPROVED W/PROVISO
  
 1. PER WPB FBC 107.2.1 AND WPB FBC 107.3.4.1, PROVIDE
 AS A DEFERRED SUBMITTAL, THE FOLLOWING:
  
 A. A MANUFACTURER?S SPECIFICATION/CUT SHEET FOR THE
 WATER HEATER; TO INCLUDE MODEL, STORAGE CAPACITY AND
 ELECTRICAL CHARACTERISTICS.
 B. A MANUFACTURER?S SPECIFICATION/CUT SHEET FOR
 EXPANSION CONTROL DEVICE; TO INCLUDE MODEL AND SIZE.
  
 THE DOCUMENTS SHALL BE SUBMITTED AS A SUPPORTING
 DOCUMENT WITH REQUIRED ARCHITECT?S STAMP AND SIGNATURE,
 APPROVED AND ON SITE PRIOR TO FINAL INSPECTION. PROCEED
 AT YOUR OWN RISK.
  
 2. PROVIDE THERMAL EXPANSION CONTROL FOR THE WATER
 HEATER COMPLYING WITH FBC PL 607.3; SEE PROVISO NOTE
 #1.B
  
 3. SUBMIT A SLAB REPAIR DETAIL FOR REVIEW AND ONCE
 APPROVED HAVE TWO (2) COPIES AT THE JOB SITE PRIOR TO
 THE FIRST INSPECTION. SHOW THE WIDTH OF THE REPAIR, THE
 MINIMUM THICKNESS OF THE CONCRTETE TO BE REPLACED, AND
 THE PSI OF THE CONCRETE. SHOW THE SIZE AND LENGTH OF
 THE DOWELS, THE MINIMUM EMBEDMENT INTO THE EXISTING
 SLAB, THE ANCHORING MATERIAL FOR THE DOWELS AND THE
 SPACING OF THE DOWELS ON CENTER. THE REPAIR SHALL ALSO
 INCLUDE TERMITE TREATMENT OF THE SOIL AND THE REQUIRED
 VAPOR BARRIER OVER WELL COMPACTED SOIL. A COPY OF THE
 TERMITE CERTIFICATE SHALL BE ONSITE FOR THE FINAL
 INSPECTION
  