Date |
Text |
2020-03-19 14:07:33 | CODES IN EFFECT: |
| FBC = FLORIDA BUILDING CODE 2017 6TH EDITION |
| WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 |
| 6TH ED, CHAPTER 1. |
| WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL |
| MANUAL REVISED 2017 |
| FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 |
| 6TH EDITION |
| FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION |
| FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION |
| FAC= FLORIDA ADMINISTRATIVE CODE |
| FS = FLORIDA STATUTES |
| |
| 19120500 648 7TH ST |
| |
| 1ST REVIEW |
| PLUMBING COMMENTS: DENIED |
| |
| 1. RE: PLAN SHEET P1.1; PLAN SHOWS SANITARY AND WATER |
| INTO UNIT AND PROVIDES NOTE , FIXTURES SHALL BE |
| PROVIDED UNDER A SEPARATE CONTRACT. PROVIDE SANITARY |
| ROUGH- IN FOR FUTURE TENANT ONLY. |
| SCOPE OF WORK IS UNCLEAR. IF IT IS THE INTENT TO STUB |
| IN WATER AND SANITARY SERVICES ONLY THEN PER WPB FBC |
| 107.2.1, INDICATE CLEARLY ON THE PLAN BY SHOWING THE |
| SERVICES TERMINATED AND CAPPED FOR FUTURE INSIDE THE |
| BUILDING. AFORE MENTIONED NOTE SHOULD STATE, FIXTURES, |
| SANITARY AND WATER ROUGH IN TO THE SAME SHALL BE |
| PROVIDED UNDER A SEPARATE CONTRACT. PROVIDE SANITARY |
| AND WATER STUB IN, TERMINATE AND CAP FOR FUTURE TENANT |
| ONLY. |
| |
| 2. DIGITAL SIGNATURE ON P1.1 IS NOT ACCEPTABLE. PER FS |
| 471 AND FAC 61G15-23.003, A DIGITAL PLAN REQUIRES A |
| DIGITAL SIGNATURE WITH THE PROPER THIRD PARTY |
| VERIFICATION. SELF-CERTIFICATION IS NOT ACCEPTABLE FOR |
| ENGINEERS. THIS APPLIES TO ANY PLAN PAGES IN THESE |
| DOCUMENTS WITH THIS DIGITAL SIGNATURE. PROVIDE |
| CORRECTION PER WPB FBC 107.1. |
| |
| END OF COMMENTS. |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| ALL PLANS TO BE DIGITALLY SIGNED BY THE DESIGNER IN |
| ACCORDANCE WITH FAC AND FS. |
| |
| |
| |
| JERALD SMITH |
| PLUMBING PLANS EXAMINER |
| CITY OF WEST PALM BEACH |
| EMAIL [email protected] |
| |
| 19120500 648 7TH ST |
| |
| |
| |
| |
| |
| |