2019-12-14 07:19:26PLAN REVIEW - BUILDING
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. SITE PLAN PAGE SP-1.01 INDICATES THE 4 FOOT HIGH
 WALL LOCATED AT THE FRONT ELEVATION OF THE PROPERTY
 ENCROACHS INTO THE 6 FOOT FPL EASEMENT. PROVIDE
 EASEMENT RELEASE FROM FPL.
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 2. REF. PLAN PAGE S-001 - PROVIDE DETAIL FOR 12X12 CMU
 PIERS.
 R606.7PIERS.
 THE UNSUPPORTED HEIGHT OF MASONRY PIERS SHALL NOT
 EXCEED 10 TIMES THEIR LEAST DIMENSION. WHERE STRUCTURAL
 CLAY TILE OR HOLLOW CONCRETE MASONRY UNITS ARE USED FOR
 ISOLATED PIERS TO SUPPORT BEAMS AND GIRDERS, THE
 CELLULAR SPACES SHALL BE FILLED SOLIDLY WITH GROUT OR
 TYPE M OR S MORTAR, EXCEPT THAT UNFILLED HOLLOW PIERS
 SHALL BE PERMITTED TO BE USED IF THEIR UNSUPPORTED
 HEIGHT IS NOT MORE THAN FOUR TIMES THEIR LEAST
 DIMENSION. WHERE HOLLOW MASONRY UNITS ARE SOLIDLY
 FILLED WITH GROUT OR TYPE M, S OR N MORTAR, THE
 ALLOWABLE COMPRESSIVE STRESS SHALL BE PERMITTED TO BE
 INCREASED AS PROVIDED IN TABLE R606.9.
 R606.7.1PIER CAP.
 HOLLOW PIERS SHALL BE CAPPED WITH 4 INCHES (102 MM) OF
 SOLID MASONRY OR CONCRETE, A MASONRY CAP BLOCK, OR
 SHALL HAVE CAVITIES OF THE TOP COURSE FILLED WITH
 CONCRETE OR GROUT.
  
 3. A 2ND SIGNATURE REVIEW WILL BE REQUIRED DUE TO NEW
 PLAN PAGES.
 UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL
 SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE
 THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG
 WITH THE CITY RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY,
 INSERT CORRECTED PAGES INTO
 SUBMITTAL AND LEAVE THE PREVIOUSLY REVIEWED SHEETS
 DETACHED.
  
  
  