Plan Review Notes For Permit 19111008 |
Permit Number |
19111008 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2019-11-20 17:04:25 | RE-ROOF BUILDING REVIEW COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | FLAT ROOF FLORIDA PRODUCT APPROVAL FL2533-R23 | | SUBMITTED: | | | | SELECTED ASSEMBLY W-15 ON PAGE 7 OF 67 DOESN'T MEET THE | | DESIGN PRESSURES FOR ALL ROOF ZONES. PROVIDE SIGNED AND | | SEALED RAS 117 CALCULATIONS FOR NAIL ENHANCING AT | | PERIMETER AND CORNER AREAS AS REQUIRED BY NOTE #9 ON | | PAGE 3 OF 67. | | SEC. 1609.1 FBC-BUILDING. | | | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|