Date |
Text |
2019-12-05 11:06:02 | THE PERMIT HAS FAILED PENDING CONFIRMATION THAT THE |
| PROPOSED CONDITIONS SENT TO THE CONTRACTOR WILL BE |
| COMPLIED WITH: |
| |
| THE PROPOSED CONDITIONS ARE AS FOLLOWS: |
| |
| A. ALL WINDOWS SHALL HAVE CLEAR GLASS OR CLEAR GLASS |
| WITH LOW-E COATING. TINTED OR PRIVACY GLASS IS |
| PROHIBITED. |
| B. ALL WINDOWS SHALL BE SIZED TO FIT THE ORIGINAL |
| WINDOW FRAME OPENING. ALL WINDOWS SHALL MATCH THE |
| INSET/DEPTH/LOCATION OF THE ORIGINAL WINDOWS WITHIN THE |
| WINDOW OPENING. |
| C. ALL WINDOW FRAMES SHALL BE WHITE IN COLOR. |
| D. WINDOWS WITH A WIDTH OF 20 INCHES AND 24 INCHES |
| SHALL HAVE A 4/4 LITE PATTERN. WINDOWS WITH A WIDTH OF |
| 28 INCHES AND 32 INCHES SHALL HAVE A 6/6 LITE PATTERN. |
| THESE WINDOWS SHALL HAVE AN EXTERNAL DIMENSIONAL OGEE |
| MUNTIN. FOR CGI SENTINEL PRODUCTS, USE THE |
| SEMI-CONTOURED (EXTERNAL ONLY) MUNTIN. |
| E. THE EXISTING MULLIONS FOR ALL WINDOWS SHALL REMAIN |
| OR BE REPLACED WITH AN ALUMINUM MULLION OF THE SAME |
| WIDTH. |
| |
| IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN |
| PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE |
| 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A |
| COMPLETED RESUBMITTAL FORM, VIA EMAIL TO |
| [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT |
| NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE |
| RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: |
| |
| HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B |
| UILDING-PERMIT-FORMS |
| |
| FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, |
| HISTORIC PRESERVATION PLANNER AT [email protected]. |
| |
| AARON BORNGRABER |
| HISTORIC PRESERVATION PLANNER |
| CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES |
| T: 561-822-1428 |
| [email protected] |
| |