Date |
Text |
2019-12-20 13:55:02 | 1ST REVIEW: |
| 2017 FLORIDA BUILDING CODE 6TH EDITION |
| 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION |
| 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH |
| EDITION |
| 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION |
| 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION |
| 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH |
| EDITION |
| 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH |
| EDITION |
| |
| PLUMBING COMMENTS: |
| |
| 1. PLEASE SHOW THE FOLLOWING ACCESSIBILITY REQUIREMENTS |
| PER FBC ACC |
| |
| 602.2 CLEAR FLOOR SPACE. UNITS SHALL HAVE A CLEAR FLOOR |
| OR GROUND SPACE COMPLYING WITH 305 POSITIONED FOR A |
| FORWARD APPROACH AND CENTERED ON THE UNIT. KNEE AND TOE |
| CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED. |
| |
| 602.4 SPOUT HEIGHT. SPOUT OUTLETS SHALL BE 36 INCHES |
| MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. |
| |
| 602.7 DRINKING FOUNTAINS FOR STANDING PERSONS. SPOUT |
| OUTLETS OF DRINKING FOUNTAINS FOR STANDING PERSONS |
| SHALL BE 38 INCHES MINIMUM AND 43 INCHES MAXIMUM ABOVE |
| THE FINISH FLOOR OR GROUND. |
| |
| 604.2 LOCATION.THE WATER CLOSET SHALL BE POSITIONED |
| WITH A WALL OR PARTITION TO THE REAR AND TO ONE SIDE. |
| THE CENTERLINE OF THE WATER CLOSET SHALL BE 16 INCHES |
| MINIMUM TO 18 INCHES MAXIMUM FROM THE SIDE WALL OR |
| PARTITION |
| |
| 604.3.1 SIZE. CLEARANCE AROUND A WATER CLOSET SHALL BE |
| 60 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE SIDE |
| WALL AND 56 INCHES MINIMUM MEASURED PERPENDICULAR FROM |
| THE REAR WALL. |
| |
| 604.4 SEATS. THE SEAT HEIGHT OF A WATER CLOSET ABOVE |
| THE FINISH FLOOR SHALL BE 17 INCHES MINIMUM AND 19 |
| INCHES MAXIMUM MEASURED TO THE TOP OF THE SEAT. SEATS |
| SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION. |
| |
| 604.5.1 SIDE WALL. THE SIDE WALL GRAB BAR SHALL BE 42 |
| INCHES LONG MINIMUM, LOCATED 12 INCHES MAXIMUM FROM THE |
| REAR WALL AND EXTENDING 54 INCHES MINIMUM FROM THE REAR |
| WALL. |
| |
| 604.5.2 REAR WALL.THE REAR WALL GRAB BAR SHALL BE 36 |
| INCHES LONG MINIMUM AND EXTEND FROM THE CENTERLINE OF |
| THE WATER CLOSET 12 INCHES MINIMUM ON ONE SIDE AND 24 |
| INCHES MINIMUM ON THE OTHER SIDE. |
| |
| 609.4 POSITION OF GRAB BARS. GRAB BARS SHALL BE |
| INSTALLED IN A HORIZONTAL POSITION, 33 INCHES MINIMUM |
| AND 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR MEASURED |
| TO THE TOP OF THE GRIPPING SURFACE |
| |
| |
| |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| THE PREVIOUSLY REVIEWED SHEETS. |
| |
| GEORGE JOHNSON |
| PLUMBING PLANS EXAMINER |
| CITY OF WEST PALM BEACH |
| 561-805-6711 |
| [email protected] |