2019-11-08 13:11:48 | BUILDING REVIEW COMMENTS: |
| |
| W.P.B. PERMIT: 19110224 |
| REVIEWED: NOVEMBER 8, 2019 |
| |
| DYLAN BATTLES |
| BUILDING PLANS EXAMINER PX4191 |
| [email protected] |
| 561-805-6718 |
| |
| FLORIDA BUILDING CODE,6TH EDITION (2017) |
| FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK |
| BELOW) |
| HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ |
| BUILDING-PERMIT-FORMS |
| FBC[B] = FBC BUILDING |
| FBC[EXISTING] = FBC EXISTING BUILDING |
| FBC[A] = FBC ACCESSIBILITY |
| FBC[E] = FBC ENERGY CONSERVATION |
| |
| IS FLOORING BEING REPLACED? |
| IF SO SEE ITEMS BELOW TO PROVIDE FOR CODE COMPLIANCE. |
| |
| 1207.2 FBC[B] FLOORING SUBMITTAL. |
| - FLOOR PLAN LAYOUT TO SHOW DIMENSIONS, AREA AND TYPE |
| OF FLOORING FOR EACH AREA. |
| |
| 1207.2 FBC[B] FLOORING SUBMITTAL. |
| - TYPE OF CEILING ASSEMBLY INCLUDING THICKNESS OF |
| CONCRETE AND IF THERE IS A SOUND RATED ASSEMBLY IN UNIT |
| BELOW. |
| |
| 1207.2 FBC[B] PLEASE ADVISE ,VIA EMAIL, WHAT FLOORING |
| AND UNDERLAYMENT ARE PROPOSED? IF THE UNDERLAYMENT |
| PRODUCT PROPOSED IS NOT ONE FOR WHICH WE HAVE TEST |
| REPORTS ON FILE, THE FOLLOWING REPORTS WILL BE |
| REQUIRED: |
| 1207.2 FBC[B] AIR-BORNE SOUND. WALLS, PARTITIONS AND |
| FLOOR/CEILING ASSEMBLIES SEPARATING DWELLING UNITS AND |
| SLEEPING UNITS FROM EACH OTHER OR FROM PUBLIC OR |
| SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS OF |
| NOT LESS THAN 50, OR NOT LESS THAN 45 IF FIELD TESTED, |
| FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM |
| E90. |
| 1207.3 FBC[B] STRUCTURE-BORNE SOUND. FLOOR/CEILING |
| ASSEMBLIES BETWEEN DWELLING UNITS AND SLEEPING UNITS OR |
| BETWEEN A DWELLING UNIT OR SLEEPING UNIT AND A PUBLIC |
| OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN |
| IMPACT INSULATION CLASS RATING OF NOT LESS THAN 50, OR |
| NOT LESS THAN 45 IF FIELD TESTED, WHEN TESTED IN |
| ACCORDANCE WITH ASTM E492. |
| 603.1 FBC[B] ALLOWABLE MATERIALS IN NON COMBUSTIBLE |
| BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL |
| INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID |
| DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED |
| TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE |
| 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 |
| OR UL 723. |
| 804.1 FBC[B] GENERAL. INTERIOR FLOOR FINISH AND FLOOR |
| COVERING MATERIALS SHALL COMPLY WITH SECTIONS 804.2 |
| THROUGH 804.4.2. EXCEPTION: FLOOR FINISHES AND |
| COVERINGS OF A TRADITIONAL TYPE, SUCH AS WOOD, VINYL, |
| LINOLEUM OR TERRAZZO, AND RESILIENT FLOOR COVERING |
| MATERIALS THAT ARE NOT COMPRISED OF FIBERS. |
| |
| -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS |
| OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) |
| SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT |
| DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER |
| SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" |
| OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS |
| APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE |
| NEED "VOID", RENDERING THEM NOT USABLE. |
| |
| PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F |
| 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME |
| [email protected] |
| |
| |
| |