Plan Review Notes For Permit 19101500 |
Permit Number |
19101500 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2019-10-30 07:46:58 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) SPECIFY THE ATTACHMENT METHOD THAT WILL BE USED TO | | INSTALL THE ROOF TILE. IF A ROOF TILE ADHESIVE IS USED, | | SUBMIT TWO COPIES OF ITS PRODUCT APPROVALS. FBC 107.2.1 | | | | 2) IF A ROOF TILE ADHESIVE IS USED, SPECIFY THE DESIGN | | PRESSURE OF THE SELF-ADHERED UNDERLAYMENT THAT WILL BE | | USED. THE DESIGN PRESSURE OF THE SELF-ADHERED | | UNDERLAYMENT IS REQUIRED TO MEET THE REQUIRED ROOF | | UPLIFT PRESSURES. FBC-R905.3 |
|