Date |
Text |
2019-12-04 12:42:46 | 1ST REVIEW |
| CODES IN EFFECT: |
| FBC = FLORIDA BUILDING CODE 2017 6TH EDITION |
| WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 |
| 6TH ED, CHAPTER 1. |
| WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL |
| MANUAL REVISED 2017 |
| FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 |
| 6TH EDITION |
| FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION |
| FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION |
| FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH |
| EDITION |
| FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION |
| FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION |
| NFPA 54 = NATIONAL FUEL GAS CODE |
| NFPA 58 = LIQUIFIED PETROLEUM GAS CODE |
| NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE |
| PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017 |
| NFPA 99 = HEALTH CARE FACILITIES CODE |
| NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES |
| FAC= FLORIDA ADMINISTRATIVE CODE |
| FS = FLORIDA STATUTES |
| |
| PLUMBING COMMENTS: |
| |
| 1. PLEASE SHOW COMPLIANCE WITH FBC ACC |
| 603.3 MIRRORS. MIRRORS LOCATED ABOVE LAVATORIES OR |
| COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE OF |
| THE REFLECTING SURFACE 40 INCHES MAXIMUM ABOVE THE |
| FINISH FLOOR OR GROUND. MIRRORS NOT LOCATED ABOVE |
| LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH THE |
| BOTTOM EDGE OF THE REFLECTING SURFACE 35 INCHES MAXIMUM |
| ABOVE THE FINISH FLOOR OR GROUND. |
| |
| 604.2 LOCATION. THE WATER CLOSET SHALL BE POSITIONED |
| WITH A WALL OR PARTITION TO THE REAR AND TO ONE SIDE. |
| THE CENTERLINE OF THE WATER CLOSET SHALL BE 16 INCHES |
| MINIMUM TO 18 INCHES MAXIMUM FROM THE SIDE WALL OR |
| PARTITION |
| |
| 604.5.1 SIDE WALL. THE SIDE WALL GRAB BAR SHALL BE 42 |
| INCHES LONG MINIMUM, LOCATED 12 INCHES (305 MM) MAXIMUM |
| FROM THE REAR WALL AND EXTENDING 54 INCHES MINIMUM FROM |
| THE REAR WALL. |
| |
| 604.5.2 REAR WALL.THE REAR WALL GRAB BAR SHALL BE 36 |
| INCHES LONG MINIMUM AND EXTEND FROM THE CENTERLINE OF |
| THE WATER CLOSET 12 INCHES MINIMUM ON ONE SIDE AND 24 |
| INCHES MINIMUM ON THE OTHER SIDE. |
| |
| 609.4 POSITION OF GRAB BARS.GRAB BARS SHALL BE |
| INSTALLED IN A HORIZONTAL POSITION, 33 INCHES MINIMUM |
| AND 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR MEASURED |
| TO THE TOP OF THE GRIPPING SURFACE |
| |
| 604.7 DISPENSERS. TOILET PAPER DISPENSERS SHALL COMPLY |
| WITH 309.4 AND SHALL BE 7 INCHES MINIMUM AND 9 INCHES |
| MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO THE |
| CENTERLINE OF THE DISPENSER. THE OUTLET OF THE |
| DISPENSER SHALL BE 15 INCHES MINIMUM AND 48 INCHES |
| MAXIMUM ABOVE THE FINISH FLOOR AND SHALL NOT BE LOCATED |
| BEHIND GRAB BARS. |
| |
| 606.3 HEIGHT. LAVATORIES AND SINKS SHALL BE INSTALLED |
| WITH THE FRONT OF THE HIGHER OF THE RIM OR COUNTER |
| SURFACE 34 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR |
| GROUND. |
| |
| 2. PROVIDE DETAIL SHOWING CLEAR FLOOR SPACE FOR TOILET |
| AND LAVATORY WITH DIMENSIONS CLEAR FLOOR SPACE SHALL |
| EXTEND UNDER FIXTURES. PER FBC ACC 606.2, 604.3.1, |
| 305.5, 305.3 |
| |
| 3. SHT LS -1 ALL THE BATHROOMS ARE LABELED UNISEX THE |
| PLUMBING CODE REQUIRES SEPARATE FACILITIES FOR EACH SEX |
| AT LEAST 2 OF THE UNISEX SHALL BE LABELED FEMALE AND |
| MALE 1 FOR EACH LOCATED IN SAME LOCATION. PER FBC PL |
| 403.2 |
| |
| 4. NOTE ON PLAN PROJECT SHALL COMPLY WITH FLORIDA |
| BUILDING CODE , PLUMBING, ACCESSIBILITY 2017 6TH |
| EDITION PER WPB AMEND TO FBC 107.2.1 |
| |
| 5. PROVIDE OCCUPANT LOAD. PER WPB AMEND TO FBC 107.2.1 |
| |
| 6. THE SIGNATURE ON THE SEAL SHALL BE AN ORIGINAL NOT A |
| COPY. PER FAC 61G15-23.003 |
| |
| 7. A SERVICE SINK IS REQUIRED. PER FBC PL TABLE 403.1 |
| |
| 8. A WATER FOUNTAIN IS REQUIRED SHOW COMPLIANCE WITH |
| FBC ACC 602.2, 602.4, 602.7, PER FBC PL TABLE 403.1 |
| |
| 9. SHT.P-1 SANITARY ISOMETRIC DRAWING, THE VENT FOR THE |
| LAVATORY IN BATHROOMS 1+2 IS MISSING VENT FOR WET VENT |
| REQUIRED ON THE LAVATORIES. PER FBC PL 912.1 |
| |
| 10. PROVIDE WATER ISOMETRIC DRAWING. PER WPB AMEND TO |
| FBC 107.3.5.1.3(13) |
| |
| 11. TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES |
| AND GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET |
| FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND |
| VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN |
| APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT |
| CONFORMS TO ASSE 1070 OR CSA B125.3. PER FBC PL 416.5 |
| |
| END OF COMMENTS. |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED |
| AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. |
| |
| GEORGE JOHNSON |
| PLUMBING PLANS EXAMINER |
| CITY OF WEST PALM BEACH |
| 561-805-6711 |
| [email protected] |