Plan Review Notes
Plan Review Notes For Permit 19101063
Permit Number 19101063
Review Stop NFIP
Sequence Number 2
Notes
Date Text
2020-01-17 07:01:08PLAN REVIEW - NFIP
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW
  
 RESULTS: DENIED
  
 PLEASE REFERENCE 2ND ELEVATION CERTIFICATE SUBMITTED
 FOR REVIEW ON 12/30/2019
  
 1. SECTION A9 (B) - STATE NUMBER OF FLOOD VENTS.
  
 2. SECTION A9 (C) - PROVIDE NET AREA OF FLOOD OPENINGS
 IN A9 (B) ABOVE.
  
 3. SECTION A9 (D) - ENGINEERED FLOOD OPENINGS - NO
 SEE NOTE ON PLAN PAGE A-1 - SMART VENT MODEL 1540-520
 TO BE INSTALLED.
 IF SMART VENT'S ARE INSTALLED, PROVIDE EVALUATION
 REPORT ISSUED BY THE INTERNATIONAL CODE COUNCIL
 EVALUATION SERVICE. (ICC ES)
  
 IF NON-ENGINEERED VENTS ARE INSTALLED, PROVIDE DETAIL
 REVIEWED AND APPROVED BY DESIGNER OF RECORD.