Plan Review Notes
Plan Review Notes For Permit 19100754
Permit Number 19100754
Review Stop P
Sequence Number 2
Notes
Date Text
2020-01-02 14:48:13CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 NFPA 58 = LIQUIFIED PETROLEUM GAS CODE
 NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017
 NFPA 99 = HEALTH CARE FACILITIES CODE
 NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 2ND REVIEW
  
  
 PLUMBING COMMENTS: DENIED
  
 1. PER WPB FBC 107.2.1, PROVIDE CLEAR FLOOR SPACES FOR
 APPLICABLE BATHROOMS TO SHOW COMPLIANCE WITH THE FAIR
 HOUSING ACT. COMPLIED
  
 2. THE SANITARY ISOMETRIC FOR THE WASHER/SHOWER/WATER
 CLOSET STACKS IS NON-COMPLIANT. PER WPB FBC 107.2.1,
 SHOW HOW THE FIXTURES ARE BEING VENTED IN ACCORDANCE
 WITH THE REQUIREMENTS OF FBC PL CHAPTER 9.
 DID NOT COMPLY: A SANITARY ISOMETRIC IS STILL REQUIRED
 TO SHOW CAPPED TUB DRAIN, CONNECTIONS OF THE TWO
 RECONFIGURED LAVATORIES AND CAPPING OF RELOCATED
 LAVATORY WHICH WAS ADJACENT TO THE SHOWER. SHOW VENTING
 AND DRAINAGE OF ALL FIXTURES AND CONNECTIONS TO STACKS.
  
 3. ANY NEW FLOOR PENETRATIONS SHALL MEET THE
 REQUIREMENTS OF FBC CHAPTER 7.
 DID NOT COMPLY
 THE WATER CLOSET FLOOR PENETRATION WILL HAVE TO BE
 RELOCATED IN ORDER TO PHYSICALLY ACCOMMODATE THE
 RECONFIGURATION OF THE FIXTURE.
 ADDITIONALLY THE DELETED TUB PENETRATION OPENING WILL
 HAVE TO BE SAFED
  
  
  
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 19100754 801 S OLIVE AVE 1105
  
  