2019-11-15 14:02:00 | RESTAURANT REVISION, BUILDING REVIEW COMMENTS |
| CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| |
| 1- PLANS NEED THE CITY PLACE STAMP ON ALLL DRAWINGS AS |
| REQUIRED BY CITY POLICY FOR ALL WORK IN CITY PLACE. |
| |
| 2- SHEET A1.1.1: |
| A) PLAN KEY NOTE #8 CALLS FOR GLASS IN EXISTING |
| STOREFRONT THAT IS PAINTED BLACK TO BE REPLACED WITH |
| NEW CLEAR GLASS TO MATCH EXISTING. DESIGNER OF RECORD |
| NEED TO PROVIDE MORE SPECIFICATIONS FOR THE TYPE OF |
| GLASS TO BE REPLACED. |
| SEC. 602.2 FBC-EXISTING BUILDING AND SPECIFY ALL THE |
| WIND DESIGN CRITERIA REQUIRED BY SEC. 1603.1.4 |
| FBC-BUILDING. |
| |
| B) CLEARLY IDENTIFY IF GLAZING IS LOCATED IN A |
| HAZARDOUS LOCATION AND PROVIDE SPECIFICATIONS. SEC. |
| 602.2 FBC-EXISTING BUILDING. |
| |
| WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |
| IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE |
| TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE |
| COMMENTS, |
| JULIO GOMEZ |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| DEVELOPMENT SERVICES DEPARTMENT |
| BUILDING DIVISION |
| (561)805-6712 |
| [email protected] |
| |