Plan Review Notes
Plan Review Notes For Permit 19100548
Permit Number 19100548
Review Stop B
Sequence Number 2
Notes
Date Text
2019-12-10 10:47:23RESIDENTIAL (R3) ALTERATION LEVEL 3, SECOND BUILDING
 REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
 PERMIT # 19100548
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES APPLY. CONTRACTOR TO
 ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME OR
 IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT
 ISSUANCE.
  
 ****IMPORTANT*****
 ENERGY CALCULATIONS NEED TO BE SIGNED/DATED BY THE
 OWNER PRIOR TO PASSING THE BUILDING REVIEW WITH
 PROVISO.
  
  
  
  
 NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
  
 1- PROVIDE ENERGY CALCULATIONS (2 COPIES) AS REQUIRED
 BY SEC. 908 FBC-EXISTING BUILDING AND SEC. R101.5
 FBC-ENERGY CONSERVATION.
 NOTE: PLEASE MAKE SURE FORMS ARE PROPERLY SIGNED BY ALL
 REQUIRED PARTIES AND IS COORDINATED WITH PLANS TO AVOID
 CONFLICTS/DELAYS.
  
 RESPONSE:
 ENERGY CALCULATIONS SUBMITTED:
 A) THE ENERGY FORM R405-2017 IS REQUIRED TO BE SIGNED
 AND DATED BY THE OWNER, ARCHITECT OR OWNER'S LEGALLY
 DESIGNATED AGENT AT THE BOTTOM OF FORM SUBMITTED AS
 REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION,
 6TH EDITION (2017) PRIOR TO RECEIVING THE PERMIT TO
 BEGIN CONSTRUCTION.
  
 B) PROVIDE COMPLETE INFORMATION ON TOP OF FORM,
 INCLUDING THE BUILDER'S NAME. SEC. R101.5.1.1.2 FBC-
 ENERGY CONSERVATION.
  
 C) ITEM #1 ON PAGE 1 OF 4 IS INCORRECT. THIS IS NOT NEW
 CONSTRUCTION. THIS IS EXISTING BUILDING. REVISE AS
 REQUIRED. SEC. R101.5.1.1.2 FBC-RESIDENTIAL.
  
 D) CONDITIONED FLOOR AREA ON ITEM #6 ON PAGE 1 OF 4 IS
 INCORRECT. REVISE AS REQUIRED. CLARIFY WHY THE AREAS
 DON'T MATCH AREAS SHOWN ON THE PROPERTY APPRAISER
 WEBSITE IF THE FOOTPRINT SEEMS TO BE THE SAME. SEC.
 R101.5.1.1.2 FBC-RESIDENTIAL.
  
 E) REVISE THE WINDOWS INFORMATION SHOWN ON PAGE 3 OF 4
 TO MATCH PLANS. REVISE OVERHANG DEPTH AND SEPARATION TO
 MATCH PLANS. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 2- OK.
  
 3- OK
  
 4- OK.
  
 5- DOOR AND WINDOWS DESIGN PRESSURES SHOWN ON SHEET 2.1
 ARE TOO LOW IF THEY ARE DONE USING TABLE R301.2(2)
 FBC-RESIDENTIAL AS SPECIFIED ON PLANS. SEE TABLE
 R301.2(2) FBC-RESIDENTIAL AND REVISE AS REQUIRED. USE
 THE LOAD ASSOCIATED WITH THE LOWER EFFECTIVE AREA AS
 REQUIRED BY FOOTNOTE "B" OF THE SAME TABLE OR PROVIDE
 CALCULATIONS FOR THE ACTUAL WINDOW SIZE BASED ON THE
 LOCATION (INTERIOR/END ZONE), MEAN ROOF HEIGHTT AND
 BUILDING EXPOSURE. SEC. 107.2.1.2 CITY AMENDMENTS.
  
 RESPONSE:
 REVISE DESIGN PRESSURES AGAIN. PRESSURES GIVEN ARE
 TAKING FROM TABLE R301.2(2) FBC-RESIDENTIAL. THIS TABLE
 IS BASED ON BUILDING EXPOSURE "B". THIS BUILDING IS IN
 EXPOSURE "C". NEED TO MULTIPLE PRESSURES BY COEFFICIENT
 SHOWN ON TABLE R301.2(3) FBC-RESIDENTIAL BASED ON THE
 HEIGH OF THE BUILDING.. REVISE AS REQUIRED. NOTE: THIS
 IS A TWO STORY BUILDING.
  
 6- OK
  
 7- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO
 INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT
 APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF
 RECORD PRIOR TO SUBMITTAL)
  
  
 A)EXTERIOR DOORS AS SHOWN ON PLANS.
 NOTE: NOA 16-0617.02 SUBMITTED IS FOR SLIDING GLASS
 DOORS. THERE ARE NOT SLIDING GLASS DOORS ON THIS
 PROJECT.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED AND CONTRACTOR DIDN'T
 SPECIFIED IF SUBMITTING LATER AS A DEFERRED SUBMITTAL.
  
 B)SINGLE HUNG WINDOWS AS SHOWN ON PLANS.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED AND CONTRACTOR DIDN'T
 SPECIFIED IF SUBMITTING LATER AS A DEFERRED SUBMITTAL.
  
 C) HURRICANE SHUTTERS IF DOORS/WINDOWS PRODUCT
 APPROVALS DON'T HAVE IMPACT GLAZING.
 PROTECTION OF OPENINGS IS REQUIRED BY SEC. R301.2.1.2
 FBC-RESIDENTIAL. SEC. 801.3 FBC-EXISTING BUILDING
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED AND CONTRACTOR DIDN'T
 SPECIFIED IF SUBMITTING LATER AS A DEFERRED SUBMITTAL.
  
 NOTE: NEED TO PROVIDE ALSO A SHUTTERS COMPLETE
 INSTALLATION SCHEDULE AS REQUIRED BY CITY
 IMPLEMENTATION STANDARD FOR WIND-BORNE DEBRIS IMPACT
 PROTECTION FOR THE FLORIDA BUILDING CODE. SEE CITY
 SAMPLE
  
 NEW COMMENT BASED ON REVISED PLANS.
 D) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY
 IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL.
 NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED.
  
 8- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS
 (INCLUDING THE ONES ALREADY SUBMITTED) AS REQUIRED BY
 SEC. 107.3.4.1 CITY AMENDMENTS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE
 TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE
 COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  