Plan Review Notes
Plan Review Notes For Permit 19100244
Permit Number 19100244
Review Stop HIST
Sequence Number 1
Notes
Date Text
2019-10-11 12:19:43THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S):
 1. A HORIZONTAL ROLLER IS AN INAPPROPRIATE WINDOW STYLE
 FOR THIS STRUCTURE. PLEASE REVISE TO TWO SINGLE-HUNG
 WINDOWS WITH A MULLION WITH AT LEAST TWO TO FOUR INCHES
 WIDE. (WINDOW #1 AND #17)
 2. A SINGLE-HUNG WINDOW IS INAPPROPRIATE FOR WINDOW
 OPENING #7 AND #9. REVISE TO A CASEMENT. THE CASEMENTS
 SHALL HAVE A 3 LITE PATTERN WITH TWO HORIZONTAL
 EXTERNAL OGEE DIMENSIONAL MUNTINS.
 3. CLARIFY OPENING #12. WHAT IS CM? I DO NOT SEE A
 PRODUCT APPROVAL INCLUDED FOR THIS OPENING.
 4. ALL SINGLE-HUNG WINDOWS WILL BE REQUIRED TO HAVE A
 6/1 LITE PATTERN WITH EXTERNAL OGEE DIMENSIONAL
 MUNTINS. PLEASE INCLUDE THIS INFORMATION ON THE PLANS.
 5. ALL PROPOSED FRENCH DOORS SHALL REPLICATE THE
 EXISTING LITE PATTERN WITH OGEE DIMENSIONAL MUNTINS.
 6. PROVIDE DETAILS OF GLASS. GLASS MUST BE CLEAR OR
 CLEAR GLASS WITH LOW-E. TINTED OR PRIVACY GLASS IS
 PROHIBITED.
  
 THE FOLLOWING ARE PROPOSED CONDITIONS OF APPROVAL,
 ADDITIONAL CONDITIONS MAY BE ADDED AFTER RESUBMITTAL.
 PLEASE CONFIRM THAT THESE CONDITIONS WILL BE COMPLIED
 WITH.
  
 A. ALL WINDOWS AND DOORS SHALL HAVE CLEAR GLASS OR
 CLEAR GLASS WITH LOW-E COATING. TINTED OR PRIVACY GLASS
 IS PROHIBITED.
 B. ALL WINDOWS AND DOORS SHALL HAVE EXTERNAL OGEE
 DIMENSIONAL MUNTINS.
 C. ALL WINDOWS SHALL BE SIZED TO FIT THE ORIGINAL
 WINDOW FRAME OPENING AND THE LOCATION/INSET/DEPTH
 WITHIN THE ORIGINAL FRAME OPENING.
  
  
 FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER,
 HISTORIC PRESERVATION PLANNER AT [email protected].
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER
 CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES
 T: 561-822-1428
 [email protected]
  