Plan Review Notes
Plan Review Notes For Permit 19091104
Permit Number 19091104
Review Stop B
Sequence Number 1
Notes
Date Text
2019-10-17 14:17:08NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW
 COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- ENERGY CALCULATIONS:
 A)MISSING THE ENERGY CALCULATIONS. PROVIDE ENERGY
 CALCULATIONS (2 COPIES) AS REQUIRED BY SEC. R101.5.1
 FBC-ENERGY CONSERVATION.
  
 B) AN ENVELOPE LEAKAGE TEST REPORT PERFORMANCE METHOD
 WAS SUBMITTED WITH THE CONTRACTOR CERTIFYING THAT THE
 ENVELOPE LEAKAGE PERFORMANCE RESULTS DEMONSTRATE
 COMPLIANCE. CONTRACTOR TO CLAREIFY HOW CAN THE
 CONTRACTOR CERTIFY THAT THE ENVELOPE LEAKAGE
 PERFORMANCE RESULTS IS IN COMPLIANCE IF THE HOSE IS NOT
 BUILT YET?
 SEC. 107.2.1 CITY AMENDMENTS.
  
 2- SURVEY SUBMITTED:
 A) SURVEY SUBMITTED IS NOT DRAWN TO SCALE. SURVEY
 SPECIFIES 1"-10' SCALE. NEED A LARGER SHEET SIZE AS
 NOTED ON SURVEY REPORT NOTE #13 OR PROVIDE SURVEY WITH
 TRUE SCALE. SEC.
 107.2.1.3 CITY AMENDMENTS.
  
 B) SURVEY SUBMITTED HAS A PRINTED COPY OF A DIGITAL
 SIGNATURE. DIGITAL SIGNATURES ARE FOR ELECTRONICALLY
 SUBMITTED DOCUMENTS. THIS IS NOT AN ELECTRONIC
 SUBMITTAL. SURVEY NEEDS ORIGINAL SEAL AND SIGNATURE AS
 REQUIRED BY SEC. 472.025 FLORIDA STATUES.
  
 3- ATTIC ACCESS SIZE SPECIFIED ON PLANS (22"X54")DON'T
 SEEM TO FIT ON THE HALLWAY THE WAY IS SHOWN ON PLANS.
 IF THIS IS THE SIZE THAT IS GOING TO BE INSTALLED, THEN
 THE OPENING NEEDS TO BE ORIENTED PERPENDICULAR TO THE
 ROOF TRUSSES AND STRUCTURAL FRAMING DETAILS WILL NEED
 TO BE PROVIDED. REVISE AS REQUIRED. SEC. R301.1
 FBC-RESIDENTIAL. SEC. 107.2.1 CITY AMENDMENTS.
  
 4- REVISE DOOR/WINDOW BUCK NOTES ON SHEET A-1. BEVELED
 BUCKS AR NOT ALLOWED. THE BUCK NEEDS TO EXTEND BEYOND
 THE INTERIOR FACE OF THE WINDOW OR DOOR FRAME AS
 REQUIRED BY SEC. R609.7.2.1 FBC-RESIDENTIAL. REVISE
 NOTES AS REQUIRED.
  
 5- ROOF SHEATHING NAILING TYPE AND SIZE SPECIFIED ON
 THE TYPICAL WALL SECTION ON SHEET S-3 DOESN'T MATCH THE
 SPECIFICATIONS SHOWN ON THE ROOF SHEATHING DIAPHRAGM
 SCHEDULE ON SHEET S-2. REVISE AS REQUIRED TO MATCH.
 SEC. R301.2.1 FBC-RESIDENTIAL.
  
 6- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO
 INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT
 APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF
 RECORD PRIOR TO SUBMITTAL):
  
 A)ENTRY DOOR AS SHOWN ON PLANS.
  
 B) ROOF SHINGLES. PROVIDE FLORIDA PRODUCT APPROVAL
 COVER PAGE THAT CORRESPONDS TO DRAWINGS SUBMITTED. NEED
 COVER PAGE TO VERIFY CURRENT CODE AND IF THE PRODUCT IS
 APPROVED.
  
 C) PRECAST LINTELS AS SPECIFIED ON PLANS.
  
 7-DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS
  
 8- TRUSS PACKAGE
 NOTE:
 TRUSS PACKAGE IS NOT REQUIRED TO BE SUBMITTED FOR PLAN
 REVIEW FOR ONE AND TWO FAMILY BUILDINGS. CONTRACTOR MAY
 DELIVER THE TRUSS PACKAGE TO THE BUILDING INSPECTOR AT
 THE TIME OF FRAMING INSPECTIONS AFTER CORRECTIONS
 ADDRESSING THE COMMENTS ARE ADDRESSED.
  
 A) ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING
 TRUSS DRAWING AND TRUSS LAYOUT AS REQUIRED BY SEC.
 107.3.4.1 CITY AMENDMENTS.
  
 B)TRUSS PACKAGE SUBMITTED NEEDS A TITLE BLOCK WITH THE
 INFORMATION OF THE TRUSS ENGINEER ON EACH SHEET AND
 EACH SHEET NEEDS TO BE SIGNED AND SEALED BY THE TRUSS
 ENGINEER AS REQUIRED BY SEC. 61G15-23.001 FAC.
  
 C) TRUSS LAYOUT TO SHOW THE TRUSS TO TRUSS CONNECTORS
 AND LOCATION. TRUSS ENGINEER TO SIGN AND SEAL THESE
 PLANS AND PROVIDE HIS INFORMATION AS REQUIRED BY FAC
 61G15-23.001. OR PROVIDE COMPLETE STRUCTURAL
 CONNECTIONS ON EACH INDIVIDUAL TRUSS DRAWING.
  
 9- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW BASED ON ALL THE SCOPE OF WORK. VALUATION TO
 INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S OVERHEAD AND
 PROFIT AND DESIGN PROFESSIONAL FEES AS REQUIRED BY SEC.
 109.3 CITY AMENDMENTS. VALUATION WAS UPDATED TO
 $201,054. THE PERMIT FEE BALANCE IS $4503.23.
  
 10-IMPACT FEES -
 PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK
 OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW.
 PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT
 AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND
 REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. PLEASE
 DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD
 DRAWINGS/DOCUMENTS FOR REFERENCE.
  
 IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE
 TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE
 COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]