2019-11-14 08:34:00 | 1ST REVIEW: |
| 2017 FLORIDA BUILDING CODE 6TH EDITION |
| 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION |
| 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH |
| EDITION |
| 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION |
| 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION |
| 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH |
| EDITION |
| 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH |
| EDITION |
| |
| PLUMBING COMMENTS: |
| |
| 1. PLEASE SHOW THE FOLLOWING REQUIRED ACCESSIBILITY |
| DETAILS PER WPB AMEND TO FBC 107.2.1 |
| |
| A)ON ALL ENLARGED BATHROOM DETAILS LABEL CLEAR FLOOR |
| SPACES FOR FBC ACC 604.3.1 SIZE. CLEARANCE AROUND A |
| WATER CLOSET SHALL BE 60 INCHES MINIMUM MEASURED |
| PERPENDICULAR FROM THE SIDE WALL AND 56 INCHES \ |
| MINIMUM MEASURED PERPENDICULAR FROM THE REAR WALL. |
| |
| B)ON ALL ENLARGED BATHROOM DETAILS AND BREAK ROOM SINK |
| LABEL CLEAR FLOOR SPACES AND SHALL BE CENTERED FOR |
| LAVATORY'S AND SINKS, FBC ACC 606.2 CLEAR FLOOR SPACE. |
| A CLEAR FLOOR SPACE COMPLYING WITH 305, POSITIONED FOR |
| A FORWARD APPROACH, AND KNEE AND TOE CLEARANCE |
| COMPLYING WITH 306 SHALL BE PROVIDED. EXCEPTIONS: 1.A |
| PARALLEL APPROACH COMPLYING WITH 305 SHALL BE PERMITTED |
| TO A KITCHEN SINK, IN A SPACE WHERE A COOK TOP OR |
| CONVENTIONAL RANGE IS NOT PROVIDED, AND TO WET BARS. |
| |
| C)FBC ACC 604.4 SEATS.THE SEAT HEIGHT OF A WATER CLOSET |
| ABOVE THE FINISH FLOOR SHALL BE 17 INCHES MINIMUM AND |
| 19 INCHES MAXIMUM MEASURED TO THE TOP OF THE SEAT. |
| SEATS SHALL NOT BE SPRUNG TO RETURN TO A LIFTED |
| POSITION. |
| |
| D)FBC ACC 604.5.1 SIDE WALL.THE SIDE WALL GRAB BAR |
| SHALL BE 42 INCHES LONG MINIMUM, LOCATED 12 INCHES |
| MAXIMUM FROM THE REAR WALL AND EXTENDING 54 INCHES |
| MINIMUM FROM THE REAR WALL. |
| |
| E)FBC ACC 604.5.2 REAR WALL.THE REAR WALL GRAB BAR |
| SHALL BE 36 INCHES LONG MINIMUM AND EXTEND FROM THE |
| CENTERLINE OF THE WATER CLOSET 12 INCHES MINIMUM ON ONE |
| SIDE AND 24 INCHES MINIMUM ON THE OTHER SIDE. |
| |
| F)609.4 POSITION OF GRAB BARS.GRAB BARS SHALL BE |
| INSTALLED IN A HORIZONTAL POSITION, 33 INCHES MINIMUM |
| AND 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR MEASURED |
| TO THE TOP OF THE GRIPPING SURFACE, |
| |
| G)FBC ACC 604.7 DISPENSERS.TOILET PAPER DISPENSERS |
| SHALL COMPLY WITH 309.4 AND SHALL BE 7 INCHES MINIMUM |
| AND 9 INCHES MAXIMUM IN FRONT OF THE WATER CLOSET |
| MEASURED TO THE CENTERLINE OF THE DISPENSER. THE OUTLET |
| OF THE DISPENSER SHALL BE 15 INCHES MINIMUM AND 48 |
| INCHES MAXIMUM ABOVE THE FINISH FLOOR AND SHALL NOT BE |
| LOCATED BEHIND GRAB BARS |
| |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| THE PREVIOUSLY REVIEWED SHEETS. |
| |
| GEORGE JOHNSON |
| PLUMBING PLANS EXAMINER |
| CITY OF WEST PALM BEACH |
| 561-805-6711 |
| [email protected] |