2019-09-23 15:04:13 | 1) SUBMIT TWO COPIES OF THE MANUFACTURER'S | | SPECIFICATIIONS FOR THE HEAT PUMP. THE HEAT PUMP SHALL | | HAVE A MINIMUM COP OF 4.0 PER THE FBC-ENERGY | | SEC.R403.10.5, WPB AMEND. TO FBC SEC. 107.2.1. | | 2) SUBMIT TWO COPIES OF THE MANUFACTURER'S | | SPECIFICATION SHEETS FOR THE MAIN DRAIN. THA MAXIMUM | | GPM DETERMINED BY THE TOTAL DYNAMIC HEAD AND THE POOL | | PUMP CURVE SHALL NOT EXCEED THE MAXIMUM GPM FLOW | | THROUGH THE MAIN DRAIN PER APSP 7, WPB AMEND. TO FBC | | SEC. 107..2.1. | | 3) PLOT THE TDH AND FLOW ON THE POOL PUMP CURVE.WPB | | AMEND. TO FBC SEC. 107.2.1. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | |
|