Plan Review Notes
Plan Review Notes For Permit 19081542
Permit Number 19081542
Review Stop B
Sequence Number 1
Notes
Date Text
2019-09-05 12:29:17JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM
 (561) 805-6716 ALTERNATE: CONTACT SAMANTHA HILL (561)
 805-6724
 [email protected]
  
 1ST REVIEW: FBC 2017 6TH EDITION
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 YOU MAY RESUBMIT UP TO TWO PAGES, ALONG WITH A
 COMPLETED RESUBMITTAL FORM, VIA EMAIL TO
 [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT
 NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE
 RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE:
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 1.FBC B 1609. SUBMITTED ENGINEERING EVALUATION RATIONAL
 ANALYSIS FOR DESIGN PRESSURE RATING FOR RAISER ROOF
 PANEL REFERENCE DESIGN CRITERIA COMPLIANCE WITH 2004
 FBC AND ASCE 7-02 WIND ZONE 150MPH. ROOF PANELS MUST
 DEMONSTRATE DESIGN CRITERIA COMPLIANCE WITH 2017 FBC
 AND ASCE 7-10 WIND ZONE 170MPH. PROVIDE TWO SETS.
 2. 61G15-23.001. F.A.C. (B). ENGINEERING SPECIFICATIONS
 AND CALCULATIONS. AN INDEX SHEET SHALL BE USED AND
 SHALL BE SIGNED, DATED AND SEALED BY EACH PROFESSIONAL
 ENGINEER WHO IS IN RESPONSIBLE CHARGE OF ANY PORTION OF
 THE ENGINEERING SPECIFICATIONS OR CALCULATIONS. THE
 INDEX SHEET MUST BE SIGNED, DATED AND SEALED BY THOSE
 PROFESSIONAL ENGINEERS IN RESPONSIBLE CHARGE OF THE
 PRODUCTION AND PREPARATION OF EACH SECTION OF THE
 ENGINEERING SPECIFICATIONS OR CALCULATIONS, WITH
 SUFFICIENT INFORMATION ON THE INDEX SHEET SO THAT THE
 USER WILL BE AWARE OF EACH PORTION OF THE
 SPECIFICATIONS OR CALCULATIONS FOR WHICH EACH
 PROFESSIONAL ENGINEER IS RESPONSIBLE.
 3. CHAPTER 61G15-23.003(1), F.A.C., THE LICENSEE SHALL
 SIGN BY HAND AN ORIGINAL OF THE LICENSEE?S SIGNATURE ON
 EACH PAGE REQUIRED TO BE SEALED. A SCANNED, FACSIMILE,
 DIGITALLY CREATED OR COPIED IMAGE OF THE LICENSEE?S
 SIGNATURE SHALL NOT BE USED.
  