2019-09-24 10:08:32RESIDENTIAL (R3) BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- CLEARLY IDENTIFY ALL ROOMS ON THE SKETCH PROVIDED.
 ALSO, CLEARLY SPECIFY TYPE AND SIZE OF EXISTING WINDOWS
 AND TYPE AND SIZE OF PROPOSED WINDOWS TO VERIFY
 COMPLIANCE WITH THE BEDROOM EGRESS REQUIREMENTS OF SEC.
 702.5 FBC-EXISTING BUILDING.
  
 2- IT IS NOT CLEAR WHAT TYPE OF WINDOWS ARE GOING TO BE
 INSTALLED. SKETCH SUBMITTED SPECIFIES SINGLE HUNG
 WINDOWS WITH FIXED TRANSOM ABOVE. BUT NOA 17-0614.14
 SUBMITTED IS FOR CASEMENT WINDOWS. CLARIFY/REVISE AS
 REQUIRED AND COORDINATE WITH ITEM #1 ABOVE. (SEC.
 107.2.1 CITY AMENDMENTS. IF USING CASEMENT WINDOWS,
 THEN NOA SUBMITTED IS OK. IF USING SINGLE HUNG WINDOWS,
 THEN NEED TO PROVIDE PRODUCT APPROVAL FOR SINGLE HUNG
 WINDOWS. SEC. 61G20-3 FAC.
  
 3- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20.3.001 FOR:
 A) WINDOW MULLIONS FOR TRANSOM WINDOWS AS SHOWN ON
 PLAN. AND CLEARLY SPECIFY MULLION SIZE TO BE USED TO
 VERIFY COMPLIANCE WITH THE CALCULATED DESIGN PRESSURES.
  
 B) SINGLE HUNG WINDOWS. COORDINATE WITH ITEM #2 ABOVE.
  
 C) ENTRY DOOR. NOTE: PROVIDE COMPLETE INSTALLATION
 DRAWINGS. ONLY DRAWING 1 OF 14 WAS SUBMITTED. SUBMIT
 ALL THE DOOR INSTALLATION DRAWINGS. 14 TOTAL.
  
 IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE
 TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE
 COMMENTS,