Plan Review Notes For Permit 19081126 |
Permit Number |
19081126 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2019-08-26 06:33:15 | 1) SUBMIT A SANITARY AND WATER RISER DIAGRAM FOR | | REVIEW. WPB AMEND. TO FBC SEC. 107.3.5.1.3. | | 2) THE WASHING MACHINE STACK SHALL BE A MINIMUM OF 3 | | INCH PER 2017 FBC-PLUMBING SEC.406.2. | | 3) SUBMIT TWO COPIES OF THE MANUFACTURER'S | | SPECIFICATIONS & INSTALLATION MANUAL FOR THE MINI LIFT | | STATION. WPB AMEND. TO FBC SEC. 107.2.1. | | 4) SUBMIT TWO COPIES OF THE MANUF. SPECS/INSTALLATION | | INSTRUCTIONS FOR THE DOG TUBS.WPB AMEND. TO FBC SEC. | | 107.2.1. | | 5) A LINT TRAP IS REQUIRED FOR THE WASHING MACHINE. | | 2017 FBC-PLUMBING SEC.1003.6. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | |
|