2019-10-30 10:59:31 | RESIDENTIAL (R3) RE-ROOF THIRD BUILDING REVIEW |
| CHECKLIST. |
| CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| |
| ORIGINAL COMMENT: |
| 1- HOUSE VALUE IS MORE THAN $300.000. NEED TO COMPLY |
| WITH THE ROOF TO WALL CONNECTIONS AS REQUIRED BY SEC. |
| 706.8 FBC-EXISTING-BUILDING. |
| SEC. 706.8: |
| WHEN A ROOF COVERING ON AN EXISTING SITE-BUILT |
| SINGLE-FAMILY RESIDENTIAL STRUCTURE IS REMOVED AND |
| REPLACED ON A BUILDING THAT IS LOCATED IN THE |
| WIND-BORNE DEBRIS REGION AS DEFINED IN THE FLORIDA |
| BUILDING CODE, BUILDING AND THAT HAS AN INSURED VALUE |
| OF $300,000 OR MORE OR, IF THE BUILDING IS UNINSURED OR |
| FOR WHICH DOCUMENTATION OF INSURED VALUE IS NOT |
| PRESENTED, HAS A JUST VALUATION FOR THE STRUCTURE FOR |
| PURPOSES OF AD VALOREM TAXATION OF $300,000 OR MORE: |
| (A)ROOF TO WALL CONNECTIONS SHALL BE IMPROVED AS |
| REQUIRED BY SECTION 706.8.1. |
| (B)MANDATED RETROFITS OF THE ROOF-TO-WALL CONNECTION |
| SHALL NOT BE REQUIRED BEYOND A 15 PERCENT INCREASE IN |
| THE COST OF REROOFING. |
| EXCEPTION: SINGLE-FAMILY RESIDENTIAL STRUCTURES |
| PERMITTED SUBJECT TO THE FLORIDA BUILDING CODE ARE NOT |
| REQUIRED TO COMPLY WITH THIS SECTION. |
| |
| RESPONSE: |
| HURRICANE MITIGATION RETROFIT LETTER FROM MARK MESIANO |
| (PROFESSIONAL ENGINEER) IS TOO GENERAL AND IT DOESN'T |
| PROVIDE SPECIFIC INFORMATION AS REQUIRED BY SEC. |
| 107.2.1 CITY AMENDMENTS. THERE ARE TOO MANY RIGHT ANGLE |
| GUSSET BRACKETS IN THE MARKET. ENGINEER NEED TO BE |
| SPECIFIC. IN ADDITION, THE ENGINEER IS NOT CLEAR WHERE |
| THE CONNECTORS ARE GOING TO BE INSTALLED. ARE THEY |
| GOING TO BE INSTALLED JUST ON THE CORNER AREAS OR ON |
| ENTIRE HOUSE. IF CORNER AREAS, THEN PROVIDE DIMENSIONS |
| OF CORNER AREAS TO BE COVERED. SEC. 107.2.1 CITY |
| AMENDMENTS |
| |
| IN ORDER TO AVOID MULTIPLE SUBMITTAL, PLEASE FEEL FREE |
| TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE |
| COMMENTS, |