Date |
Text |
2019-08-20 12:19:02 | JONATHAN BROOKS JR. |
| BUILDING PLANS EXAMINER |
| WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM |
| (561) 805-6716 ALTERNATE: CONTACT SAMANTHA HILL (561) |
| 805-6724 |
| [email protected] |
| |
| 1ST REVIEW: FBC 2017 6TH EDITION |
| FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) |
| FBC B = FBC BUILDING |
| FBC R = FBC RESIDENTIAL |
| FBC EB = FBC EXISTING BUILDING |
| FBC A = FBC ACCESSIBILITY |
| FBC EC = FBC ENERGY CONSERVATION |
| WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC |
| RESULTS: DENIED |
| YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED |
| BELOW. |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| YOU MAY RESUBMIT UP TO TWO PAGES, ALONG WITH A |
| COMPLETED RESUBMITTAL FORM, VIA EMAIL TO |
| [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT |
| NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE |
| RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: |
| HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B |
| UILDING-PERMIT-FORMS |
| |
| 1.FBC B 107.2.1. ON THE SCHEDULE FOR INSTALLATION OF |
| PROTECTIVE DEVICES OR ASSEMBLIES: PLEASE CORRECT THE |
| FOLLOWING; COLUMN HEADING ?SHUTTER GLASS SEPARATION?; |
| PROVIDE INFORMATION FROM SHEET 11 FL1850. COLUMN |
| HEADING ?MINIMUM EDGE DISTANCE?; PROVIDE INFORMATION |
| FROM SHEET 13 FL1850. COLUMN HEADING ?ANCHOR SPACING?; |
| PROVIDE INFORMATION FROM PAGES 12-15 FL1850. EXAMPLE: |
| POURED CONCRETE, MOUNTING TYPE L, MAXIMUM SPAN 8?-0?, |
| 40 (PSF), USING TAPCON WITH ADVANCED THREADFORM |
| TECHNOLOGY THE MAXIMUM ANCHOR SPACING IS 5?. |
| 2. WHEN COMPLETING THE INSTALLATION SCHEDULE, PLEASE |
| NOTE PAGE 13 OF 20, FACTORS APPLY DEPENDING ON |
| SUBSTRATE, EDGE DISTANCE AND FASTENER. FOR FASTENER, IF |
| USING TAPCON, BE SPECIFIC AS TO WHICH TAPCON (TAPCON |
| W/ADVANCED THREADFORM TECHNOLOGY REQUIRES A .9 FACTOR). |
| REDUCE ANCHOR SPACING BY MUTIPLYING SPACING SHOWN ON |
| SCHEDULE BY THE FACTOR. |
| |