Plan Review Notes For Permit 19080726 |
Permit Number |
19080726 |
|
Review Stop |
G |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2019-08-22 12:54:53 | 1) ) SUBMIT TWO COPIES OF THE APPLICABLE SIZING TABLES | | USED TO SIZE THE GAS SYSTEM OR PLACE A NOTE ON THE | | PLANS/DRAWINGS SPECIFYING WHICH SIZING TABLE(S) FROM | | THE GAS CODE OR OTHER STANDARD THAT WERE USED IN THE | | DESIGN OF THIS GAS SYSTEM. REFER TO THE 2017 FBC-FUEL | | GAS SECS. 401.4, 401.8, 402.3, AND TABLES 402.4 (1) | | THRU 402.4 (37) OR 2017 FBC-RES. SEC. G2413.3, G2412.8, | | G2413.1, G2413.2, & G2413.3. | | 2) SHOW THE CORRESPONDING EHD NUMBER OF THE CORRUGATED | | STAINLESS STEEL TUBING ON THE PLANS. | | 3) SHOW THE LOCATION OF THE REGULATOR FOR TANKLESS | | WATER HEATER. | | 4) SHOW THE BTU LOAD OF THE COOKTOP AND THE TANKLESS | | WATER HEATER ON THE PLANS. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | |
|