Plan Review Notes For Permit 19080670 |
Permit Number |
19080670 |
|
Review Stop |
P |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2019-10-01 13:05:08 | 1) THE 2 INCH WASHING MACHINE DRAIN SHALL CONNECT TO A | | MINIMUM 3 INCH WASTE STACK.2017 FBC-PLUMBING TABLE | | 709.1 FOOTNOTE G.2ND REQUEST. | | 2) THE HOT WATER LINE ON THE TANKLESS WATER HEATER | | SHALL BE INSUKATED. 2017 FBC-ENERGY SEC.R403.5.3.2ND | | REQUEST | | 3) SUBMIT TWO COPIES OF THE MANUFACTURER'S | | SPECIFICATIONS FOR THE TANKLESS WATER HEATER.WPB AMEND. | | TO FBC SEC. 107.2.1. 2ND REQUEST | | 4) THE MAIN PERMIT WAS FOR THE REPAIR OF THE BACK PORCH | | AND THE REVISION SHOWS A PARTIAL WALL ON THE INTERIOR | | AND A POCKET DOOR. SUBMIT COMPLETE PLANS FOR THE | | BUILDOUT OF THIS TOILET ROOM WPB AMEND. TO FBC SEC. | | 107.2.1. 2ND REQUEST. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | |
|