Plan Review Notes
Plan Review Notes For Permit 19080670
Permit Number 19080670
Review Stop P
Sequence Number 1
Notes
Date Text
2019-08-30 13:26:401) THE 2 INCH WASHING MACHINE DRAIN SHALL CONNECT TO A
 MINIMUM 3 INCH WASTE STACK.2017 FBC-PLUMBING TABLE
 709.1 FOOTNOTE G.
 2) THE HOT WATER LINE ON THE TANKLESS WATER HEATER
 SHALL BE INSUKATED. 2017 FBC-ENERGY SEC.R403.5.3.
 3) SUBMIT TWO COPIES OF THE MANUFACTURER'S
 SPECIFICATIONS FOR THE TANKLESS WATER HEATER.WPB AMEND.
 TO FBC SEC. 107.2.1.
 4) SHOW LENGTH AND WIDTH DIMENSIONS OF THE POWDER ROMM.
 PLUMBING FIXTURES SHALL BE LOCATED IN ACCORDANCE WITH
 2017 FBC-PLUMBING SEC. 405.3.1.
 5) THE MAIN PERMIT WAS FOR THE REPAIR OF THE BACK PORCH
 AND THE REVISION SHOWS A PARTIAL WALL ON THE INTERIOR
 AND A POCKET DOOR. SUBMIT COMPLETE PLANS FOR THE
 BUILDOUT OF THIS TOILET ROOM WPB AMEND. TO FBC SEC.
 107.2.1.
  