Plan Review Notes
Plan Review Notes For Permit 19080089
Permit Number 19080089
Review Stop P
Sequence Number 1
Notes
Date Text
2019-09-10 18:42:161ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. SHT P-1 THE UPSTREAM WASHING MACHINE IS NOT VENTED
 PLEASE SHOW VENT ON SANITARY ISOMETRIC. PER FBC PL
 901.2.1
  
 2. SHT P-1 PLEASE SIZE ALL PIPING ON SANITARY
 ISOMETRIC. THE BRANCH DRAIN TO NEW WASHERS SHALL BE 3"
 MIN. PER FBC PL 406.2
  
 3. A LINT TRAP IS REQUIRED ON WASHER DRAINS. PER FBC PL
 1003.6
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  