2020-08-19 11:14:57 | PERMIT 19070579 - UNDERGROUND FIBER MCIMETRO PROJECT |
| #1801BSBK.79 NORTHPOINT PARKWAY - 1ST RESUBMITTAL |
| |
| PROVIDE WRITTEN RESPONSE TO COMMENTS. |
| |
| THE FOLLOWING ITEMS NEED TO BE ADDRESSED OR THE PERMIT |
| WILL NOT BE APPROVED. |
| |
| 1) THE MAJORITY OF THE FIBER RUN IS SHOWN ON PRIVATE |
| PROPERTY WITHIN THE UTILITY EASEMENT. WIRELESS |
| COMMUNICATION FACILITY WORK ON PRIVATE PROPERTY WITHIN |
| A UTILITY EASEMENT IS NOT SUBJECT TO A WIRELESS |
| COMMUNICATION FACILITIES IN A RIGHT-OF-WAY PERMIT. THE |
| PERMIT WILL APPLY TO THE SECTION WHERE THE BORE CROSSES |
| NORTHPOINT PARKWAY. THE MOT AND A RIGHT-OF-WAY PERMIT |
| FOR ANY USE OF THE RIGHTS-OF-WAY WILL STILL BE REQUIRED |
| FOR THE WORK WITHIN THE EASEMENT. |
| |
| 2) ENGINEERING PLAN - |
| |
| A. REGARDLESS OF THE STATEMENT IN COMMENT 1, ABOVE, |
| PLEASE PROVIDE VERIFICATION THAT THE PROPOSED TIE IN AT |
| 11+75 WILL NOT DAMAGE THE ROOT ZONE OF THE ADJACENT |
| TREES. |
| |
| B. THE BORE SHOWN AT 12 FEET BELOW GRADE IS AT A |
| SUFFICIENT DEPTH TO AVOID TREE AND PALM DAMAGE. |
| |
| C. STAFF WILL NOT APPROVE THE INSTALLATION OF A SIX (6) |
| FOOT TALL MARKER POLE ADJACENT TO THE HANDHOLES (SHOWN |
| ON SHEET 8). STAFF HAS REVIEWED A NUMBER OF MCIMETRO |
| APPLICATIONS THAT COMPLY WITH THIS REQUIREMENT, SO THIS |
| APPLICATION NEEDS TO SHOW THE SAME. |
| |
| PLEASE NOTE: |
| |
| THE INSTALLATION CONTRACTOR MUST CONTACT SUNSHINE 811 |
| TO VERIFY THE LOCATION OF ALL UTILITIES AND VERIFY ALL |
| DEPTHS PRIOR TO CONSTRUCTION. ALL CITY UTILITIES MUST |
| BE LOCATED BY SOFT DIG METHODS BEFORE STARTING THE |
| WORK. |
| |
| THE RIGHT-OF-WAY USE PERMIT REQUIRES YOU TO PROVIDE A |
| CERTIFICATE OF LIABILITY INSURANCE, WHICH IN ACCORDANCE |
| WITH SECTION 78-406 OF THE CITY CODE SPECIFICALLY NAMES |
| THE CITY OF WEST PALM BEACH, ITS COMMISSIONERS, |
| OFFICERS, EMPLOYEES AND AGENTS AS ADDITIONAL INSURED. |
| |
| CONTACT ERIC SCHNEIDER @ (561) 822-1446 |
| [email protected] |
| |