Plan Review Notes
Plan Review Notes For Permit 19070350
Permit Number 19070350
Review Stop B
Sequence Number 2
Notes
Date Text
2019-09-10 18:44:21BUILDING REVIEW APPROVED WITH PROVISO:
  
 SEC. 3306.2 FBC WALKWAYS.
 A WALKWAY SHALL BE PROVIDED FOR PEDESTRIAN TRAVEL IN
 FRONT OF EVERY CONSTRUCTION AND DEMOLITION SITE UNLESS
 THE APPLICABLE GOVERNING AUTHORITY AUTHORIZES THE
 SIDEWALK TO BE FENCED OR CLOSED. WALKWAYS SHALL BE OF
 SUFFICIENT WIDTH TO ACCOMMODATE THE PEDESTRIAN TRAFFIC,
 BUT IN NO CASE SHALL THEY BE LESS THAN 4 FEET (1219 MM)
 IN WIDTH. WALKWAYS SHALL BE PROVIDED WITH A DURABLE
 WALKING SURFACE. WALKWAYS SHALL BE ACCESSIBLE IN
 ACCORDANCE WITH CHAPTER 11 AND SHALL BE DESIGNED TO
 SUPPORT ALL IMPOSED LOADS AND IN NO CASE SHALL THE
 DESIGN LIVE LOAD BE LESS THAN 150 POUNDS PER SQUARE
 FOOT (PSF) (7.2 KN/M2).
  
 SEC. 3306.7 FBC COVERED WALKWAYS.
 COVERED WALKWAYS SHALL HAVE A CLEAR HEIGHT OF NOT LESS
 THAN 8 FEET (2438 MM) AS MEASURED FROM THE FLOOR
 SURFACE TO THE CANOPY OVERHEAD. ADEQUATE LIGHTING SHALL
 BE PROVIDED AT ALL TIMES. COVERED WALKWAYS SHALL BE
 DESIGNED TO SUPPORT ALL IMPOSED LOADS. IN NO CASE SHALL
 THE DESIGN LIVE LOAD BE LESS THAN 150 PSF (7.2 KN/M2)
 FOR THE ENTIRE STRUCTURE
  