2019-07-19 19:00:27PLAN
 REVIEW COMMENTS
  
 2ND REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) COMPLIED.
  
 2) COMPLIED.
  
 3) PARTIALLY COMPLIED. THE INFORMATION PROVIDED IS
 INCOMPLETE. THE INSTALLATION SCHEDULE SPECIFIES THAT
 THE SUBSTRATE IS WOOD FOR BOTH THE FIRST AND SECOND
 FLOORS. THE PROPERTY APPRAISER'S WEBSITE INDICATES THAT
 THE FIRST FLOOR IS CBS AND THE SECOND FLOOR IS WOOD
 FRAME STUCCO. THE ACCORDION SHUTTERS ARE ALWAYS
 INSTALLED VERTICALLY NOT HORIZONTALLY AS SPECIFIED ON
 THE SCHEDULE. THE TYPE OF ANCHOR IS LISTED AS ALL POINT
 SOLID SET IN ONE PLACE AND TAPCON 2 1/4" IS LISED IN
 THE SCHEDULE. THE SHUTTER MOUNTING IS SPECIFIED AS #14
 AND I WAS UNABLE TO DETERMINE WHICH MOUNTING YOU WILL
 USE. PLEASE CIRCLE THE MOUNTINGS AND ANCHOR SPACINGS
 YOU WILL USE IN THE PRODUCT APPROVAL DETAILS AND ANCHOR
 SCHEDULES. FBC 107.2.1 FBC - R 301.2.1.2 SUBMIT TWO
 COPIES OF AN INSTALLATION SCHEDULE AND KEY PLAN FOR THE
 STORM PANELS. SPECIFY THE OPENING SIZE, THE WIND
 PRESSURES, TYPE OF ANCHOR, ANCHOR SPACING, EDGE
 DISTANCE, PANEL LENGTH, PANEL SPAN, SEPARATION DISTANCE
 FROM PANEL TO GLASS AND THE APPLICABLE SECTION NUMBER
 FROM THE INSTALLATION DRAWINGS. I HAVE INCLUDED A LINK
 TO THE CONSTRUCTION SERVICES DEPARTMENT SITE THAT HAS
 MANY OF THE RELATED FORMS INCLUDING THE SCHEDULE FOR
 INSTALLATION OF OPENING PROTECTIVE DEVICES.
 HTTP://WPB.ORG/DEVELOPMENT/FORMS-AND-PUBLICATIONS/
  
  
  
  