Plan Review Notes For Permit 19061153 |
Permit Number |
19061153 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2019-06-25 08:15:37 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | 1- FLAT ROOF NOA 15-1201.09 SUBMITTED: SELECTED | | ASSEMBLY ON PAGE 41 OF 49 DOESN'T MEET THE DESIGN | | PRESSURES FOR ALL ROOF ZONES. NEED TO PROVIDE SIGNED | | AND SEALED RAS 117 CALCULATIONS (2 COPIES) AS REQUIRED | | BY LIMITATION #7 ON LAST PAGE OF NOA. NEED THE | | CALCULATIONS TO MEET THE DESIGN PRESSURES REQUIRED BY | | SEC. R301.2.1 FBC-RESIDENTIAL. | | NOTE: TAKE INTO CONSIDERATION THAT BUILDING IS LOCATED | | IN EXPOSURE D. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|